HB-MCP 2 Way Manual Valve, Normally Closed, Push Type
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, manual valve, 2 way normally closed, push type.
OPERATION
The HB-MCP blocks flow from (2) to (1) until an operator pushes the knob in allowing pressure at port #2 to
drop to port #1 pressure.
FEATURES
Hardened parts for long life.
Industry common cavity.
HYDRAULIC SYMBOL
Good as a pilot dump valve.
Port #1 should be limited to < 500 PSI to allow actuation (50
lbs), Port #2 actuation load at 4000 PSI (50 lbs).
PERFORMANCE
Actual Test Data (Cartridge Only)
VALVE SPECIFICATIONS
Nominal Flow 1 GPM (4 LPM)
Max. Operating Pressure 4000 PSI (276 bar)
Typical Internal Leakage
(150 SSU)
5 drops/min
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating
Temperature Range
32° to 160° F (0° to 70° C)
Weight .14 lbs. (.06 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque
Requirements
25 ft-lbs (34 Nm)
Cavity POWER 2W
Cavity Form Tool (Finishing) 40500005
Seal Kit 21191100
- Port 2 to 1
0
500
1000
1500
2000
2500
3000
3500
4000
00.20.40.60.81
Flow (GPM)
Pressure Drop (PSI)
0
50
100
150
200
250
0123
Flow (LPM)
Pressure Drop (BAR)
Page 300
MECHANICAL DIRECTIONAL CONTROLS
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
HB-MCP - -
OPTIONS BODIES Note: Aluminum NOT durability rated for
Buna, Knob
0K
Blank Without Body 4000 PSI. Consult factory for options.
Viton, Knob
VK N
1/4 NPTF Ports
S
#6 SAE Ports
Page 301