Page PD66
PROPORTIONAL CONTROLS
Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: tecnord@tecnord.com • www.tecnord.com
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 7 / 2017
DESCRIPTION
8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 3 position, Cylinder Spool, proportional directional
valve.
OPERATION
EQ-S4P, when de-energized, blocks ow to all ports. When coil (S1) is energized, ow is allowed from (3) to
(4), and from (2) to (1). When coil (S2) is energized, ow is allowed from (3) to (2), and from (4) to (1). Flow is
proportional to the current applied to the coil. A compensator must be used to create a pressure compensated
ow control function.
FEATURES
• Hardened parts for long-life.
• Industry common cavity.
• Excellent linearity and low hysteresis characteristics.
• Cartridges are voltage interchangeable.
• Optional coil voltages and terminations available.
• Unitized, molded coil design.
• Continuous duty rated solenoid.
Flow Range See curves for various versions
Max System Pressure 3500 PSI (241 bar)
Leakage 10 cu-in/min
160 cc/min bar @ 210 bar
Hysteresis ±5%
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -30°C / +100°C
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 18 ft-lbs (26 Nm)
Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)
Cavity POWER 4W
Cavity Tools Kit
(form tool, reamer, tap) 40500029
Current Supply Characteristics PWM (Pulse Width Modulation)
Rated Current Range 400-1400 mA
PWM or Super-Imposed
Dither Frequency 100-200 Hz
Coil Resistance (12 VDC) 6.85 Ohm ±5% at 68°F (20°C)
0
8
4
12
Flow vs. Current
16
20
Flow (L/min)
From 2 to 1
From 2 to 3
Current (mA)
200
400 600 800
1000
1200
Regulated Flow (L/min)
0
6
9
3
150
50 200
12
15
100
250
Differential Pressure (bar)
Pressure Compensation from inlet to work port
EQ-S4P 4 WAY 3 POSITION, CYLINDER SPOOL, PROPORTIONAL DIRECTIONAL VALVE
COIL SPECIFICATIONS
VALVE SPECIFICATIONS
HYDRAULIC SYMBOL
PERFORMANCE
0
8
4
12
16
20
From 2 to 1
From 2 to 3
200
400 600 800
1000
1200
Regulated Flow (L/min)
0
6
9
3
150
50 200
12
15
100
250
Differential Pressure (bar)
Pressure Compensation from inlet to work port
Flow (l/min)
Current (mA)
Flow vs. Current
Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)
(3) (1)
(2) (4)