Page PD68
PROPORTIONAL CONTROLS
Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: tecnord@tecnord.com • www.tecnord.com
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 7 / 2017
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, Cylinder Spool, proportional directional
valve.
OPERATION
EG-S4P, when de-energized, blocks ow to all ports. When coil (S1) is energized, ow is allowed from (3) to
(4), and from (2) to (1). When coil (S2) is energized, ow is allowed from (3) to (2), and from (4) to (1). Flow is
proportional to the current applied to the coil. A compensator must be used to create a pressure compensated
ow control function.
FEATURES
Hardened parts for long-life.
Industry common cavity.
Excellent linearity and low hysteresis characteristics.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations available.
Unitized, molded coil design.
Continuous duty rated solenoid.
Flow Range See curves for various versions
Max System Pressure 3500 PSI (241 bar)
Leakage 15 cu-in/min
250 cc/min bar @ 210 bar
Hysteresis ±5%
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -30°C / +100°C
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 25 ft-lbs (34 Nm)
Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)
Cavity DELTA 4W
Cavity Tools Kit
(form tool, reamer, tap) 40500002
Current Supply Characteristics PWM (Pulse Width Modulation)
Rated Current Range 400-1400 mA
PWM or Super-Imposed
Dither Frequency 100-200 Hz
Coil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)
Pressure Compensation from inlet to work port



0 200 600
10
5
15
800
Current (mA)
Flow vs. Current
20
25
Flow (l/min)
30
1200
From 2 to 3
1000
600400
From 2 to 1
EG-S4P 4 WAY 3 POSITION, CYLINDER SPOOL, PROPORTIONAL DIRECTIONAL VALVE
COIL SPECIFICATIONS
VALVE SPECIFICATIONS
HYDRAULIC SYMBOL
PERFORMANCE
Flow vs. Current
Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)
Pressure Compensation from inlet to work port



0 200 600
10
5
15
800
Current (mA)
Flow vs. Current
20
25
Flow (l/min)
30
1200
From 2 to 3
1000
600400
From 2 to 1
Flow (l/min)
Current (mA)
(3) (1)
(2) (4)
Page PD69
PROPORTIONAL CONTROLS
Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: tecnord@tecnord.com • www.tecnord.com
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 7 / 2017
S4P
S4M
Pressure Drop vs. Flow


S2
S1





Pressure Compensation from inlet to work port



0 200 600
10
5
15
800
Current (mA)
Flow vs. Current
20
25
Flow (l/min)
30
1200
From 2 to 3
1000
600400
From 2 to 1
S4P
S4M
Pressure Drop vs. Flow


S2
S1





DIMENSIONS
(for bodies style and sizes see section “Accessories”)
ORDERING INFORMATION
NOTES: for other seals, consult factory.
Approximate Coil Weight: .47 lbs (.21 kg)
EG-S4P – – – –
OPTIONS BODIES
Buna Standard B0 Up to 22 l/min Blank Without Body
N 3/8” BSP Ports
S #6 SAE Ports
VOLTAGE
12 12 VDC
24 24 VDC
“L” COIL TERMINATION
HC DIN 43650 (Hirschmann)
DT Deutsch-Integral DT04-2P
Pressure Drop vs. Flow
Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)
Pressure Compensation from Inlet to Work Port
Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)
Regulated Flow (l/min)
Differential Pressure (bar)
Flow (l/min)
Pressure Drop (bar)