Page PD64
PROPORTIONAL CONTROLS
Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: tecnord@tecnord.com • www.tecnord.com
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 7 / 2017
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, Motor Spool, proportional directional
valve.
OPERATION
EG-S4M, when de-energized, blocks ow at (2) and allows ow between (1), (3) and (4). When coil (S1) is
energized, ow is allowed from (3) to (4), and from (2) to (1). When coil (S2) is energized, ow is allowed from (3)
to (2), and from (4) to (1). Flow is proportional to the current applied to the coil. A compensator must be used to
create a pressure compensated ow control function.
FEATURES
• Hardened parts for long-life.
• Industry common cavity.
• Excellent linearity and low hysteresis characteristics.
• Cartridges are voltage interchangeable.
• Optional coil voltages and terminations available.
• Unitized, molded coil design.
• Continuous duty rated solenoid.
Pressure Compensation from inlet to work port
0 200 600
10
5
15
800
Current (mA)
Flow vs. Current
20
25
Flow (l/min)
30
1200
From 2 to 3
1000
600400
From 2 to 1
Pressure Compensation from inlet to work port
0 200 600
10
5
15
800
Current (mA)
Flow vs. Current
20
25
30
From 2 to 3
From 2 to 1
Flow Range See curves for various versions
Max System Pressure 3500 PSI (241 bar)
Leakage 15 cu-in/min
250 cc/min bar @ 210 bar
Hysteresis ±5%
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -30°C / +100°C
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 25 ft-lbs (34 Nm)
Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)
Cavity DELTA 4W
Cavity Tools Kit
(form tool, reamer, tap) 40500002
Current Supply Characteristics PWM (Pulse Width Modulation)
Rated Current Range 400-1400 mA
PWM or Super-Imposed
Dither Frequency 100-200 Hz
Coil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)
EG-S4M 4 WAY 3 POSITION, MOTOR SPOOL, PROPORTIONAL DIRECTIONAL VALVE
COIL SPECIFICATIONS
VALVE SPECIFICATIONS
HYDRAULIC SYMBOL
PERFORMANCE
Flow (l/min)
Current (mA)
Flow vs. Current
Coil 12 VDC - 130 Hz PWM - Oil 26 cSt (121 SSU) @ 50°C (104°F)
(3) (1)
(2) (4)