EE-P2H 2 Way, Normally Open, Proportional Flow Control Valve
DESCRIPTION
10 size, 7/8-14 thread, solenoid operated, 2 way normally open, proportional ow control valve.
OPERATION
When de-energized the EE-P2H allows ow from (1) to (2).
When fully energized, the valve blocks ow at port (1) and (2). Flow is proportional to current applied to the
coil. A compensator must be used to create a pressure compensated ow control function.
OPERATION OF MANUAL OVERRIDE OPTION: To override, turn the manual override screw clockwise.
To release turn the manual override screw counter-clockwise.
FEATURES
• Ecient wet-armature construction.
• Cartridges are voltage interchangeable.
•
Industry common cavity.
• Unitized, molded coil design.
• Continuous duty rated solenoid.
• Optional coil voltages and terminations.
HYDRAULIC SYMBOL
Curve is attained with compensator at
with various settings.
SNOITACIFICEPSEVLAVECNAMROFREP
Flow range See curve
Max System Pressure 3500 PSI (245 bar)
tanim/cc001xamegakaeL 245 bar
Hysteresis + / - 4%
Viscosity Range
36 to 3000 SSU (3 to 647
cSt)
31/61/81OSInoitartliF
Media Operating
Temperature Range
-40 ° to 250 ° F(-40 ° to
120° C)
)gk62.(.sbl85.thgieW
Operating Fluid Media
General Purpose
Hydraulic Fluid
Cartridge Torque
Requirements
26 ft-lbs (35 Nm)
Coil Nut Torque
Requirements
2-3 ft-lbs (3-4 Nm)
W2ATLEDytivaC
Cavity Tools kit (form tool,
reamer, tap)
40500000
00219112tiKlaeS
COIL SPECIFICATIONS
Current Supply
Characteristics
PWM
Rated Current Range
0 – 1450 mA
PWM or Super-imposed
Dither Frequency
100 - 150 Hz
Flow (l/min) vs. Current (mA)
(12 V coil; Delta P = 5, 14, 20 bar; Toil = 40°C)
Coil Resistance (12 Vdc)
7,5 Ohm +/- 5% at 68 °F
(20 ° C)
PROPORTIONAL FLOW CONTROLS
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specic application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
Page 522