EE - P2G 2 Way, Normally Closed, Proportional Flow Control Valve
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, proportional flow control
valve.
OPERATION
When de-energized the EE-P2G blocks flow at ports (1) and (2).
When energized, the valve allows flow from (2) to (1). Flow is proportional to the current applied to the coil.
A compensator must be used to create a pressure compensated flow control function.
OPERATION OF MANUAL OVERRIDE OPTION: To override, turn the manual override screw clockwise.
To release turn the manual override screw counter-clockwise.
FEATURES
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Industry common cavity.
Unitized, molded coil design.
Continuous duty rated solenoid.
Optional coil voltages and terminations.
HYDRAULIC SYMBOL
Curves are attained with compensator.
PE SNOITACIFICEPSEVLAVECNAMROFR
Flow range See curves for various versions
Max System Pressure 3500 PSI (245 bar)
Leakage max 50 cc/min at 245 bar
Hysteresis + / - 3%
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
31/61/81OSInoitartliF
Media Operating
Temperature Range
-40 to 250 F (-40 to 120 C)
)gk62.(.sbl85.thgieW
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque
Requirements
26 ft-lbs (35 Nm)
Coil Nut Torque
Requirements
2-3 ft-lbs (3-4 Nm)
W2ATLEDytivaC
Cavity Tools kit (form tool,
reamer, tap)
40500000
Seal Kit
21191200
COIL SPECIFICATIONS
Current Supply
Characteristics
PWM (Pulse Width Modulation)
Rated Current Range
200 – 1450 mA
PWM or Super-imposed
Dither Frequency
100 - 150 Hz
Coil Resistance (12 Vdc)
7.2Ohm+/-5%at68 F(20C)
Flow (l/min) vs. Current (mA)
(12 V coil; Delta P = 14 bar ; Toil = 40°C)
“B ” version - Flow (l/min) vs. Current (mA)
(12 V coil; Delta P = 14 bar ; Toil = 40°C)
“B ” version -
A
PROPORTIONAL FLOW CONTROLS
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specic application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
Page 512