EE - P2A 2 Way, Normally Closed, Proportional Flow Control Valve
DESCRIPTION
10 size, 7/8-14 thread, solenoid operated, 2 way normally closed poppet style, proportional flow control
valve.
OPERATION
When de-energized the EE-P2A blocks flow from (1) to (2) and allows reverse flow from(2) to (1).
When energized, the valve allows flow from (1) to (2). Flow is proportional to current applied to the coil.
A compensator must be used to create a pressure compensated flow control function.
FEATURES
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Industry common cavity.
Unitized, molded coil design.
Continuous duty rated solenoid.
Optional coil voltages and terminations.
HYDRAULIC SYMBOL
Curves are attained without pressure compensator.
The valve can work with a pressure drop up to 200 bar
SNOITACIFICEPSEVLAVECNAMROFREP
“A” version - Flow (l/min) vs. Current (mA)
(12 V coil; Toil = 40° C)
B” version - Flow (l/min) vs. Current (mA)
(12 V coil; Toil = 40° C)
sevruceeSegnarwolF
Max System Pressure 3500 PSI (245 bar)
rab542@nim/spord01-0egakaeL
%3-/+siseretsyH
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
31/61/81OSInoitartliF
Media Operating Temperature
Range
-40
to 250 F (-40 to 120 C)
)gk23.(.sbl27.thgieW
Operating Fluid Media
General Purpose Hydraulic
Fluid
Cartridge Torque
Requirements
37 ft-lbs (50 Nm)
Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)
W2ATLEDytivaC
Cavity Tools kit (form tool,
reamer, tap)
40500000
00219112tiKlaeS
COIL SPECIFICATIONS
Current Supply Characteristics
PWM
Rated Current Range
500 1450 mA
PWM or Super-imposed Dither
Frequency
100 Hz
Coil Resistance (12 Vdc)
7,5 Ohm +/- 5% at 68
F
(20
C)
PROPORTIONAL FLOW CONTROLS
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specic application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
Page 516
ORDERING INFORMATION
EE - P2A - -
OPTIONS
Buna Standard 00
Viton Standard V0
Buna, screw type override(Knob) OS
VE
A
B
C
DIMENSIONS
“C” version
- Flow (l/min) vs. Current (mA)
(12 V coil; Toil = 40° C)
(for bodies style and sizes see section “Accessories”)
-- -
BODIES
Blank Without Body
S #8 SAE Ports
VOLTAGE
12 12 VDC
24 24 VDC
“F” COIL TERMINATION
HC DIN 43650 (Hirschman)
DI Deutsch-Integral DT04-2P
JT AMP Jr. Timer
ERSION
Up to 15 l/min
Up to 30 l/min
Up to 45 l/min
NOTES:
1) Flows refer to a 14 bar Delta P
2) For other seals, consult factory
Approximate Coil Weight: .47lbs. (.21 kg.)
OPTIONS
Buna standard
Buna, screw type override (Knob)
Buna, screw type override (Grad. Knob)
Buna, screw type override (Grad. Knob)
Buna, screw type override (Grad. Knob)
A0 Up to 15 l/min
AS Up to 15 l/min
AK Up to 15 l/min
Buna standard
Buna, screw type override (Knob)
B0 Up to 30 l/min
BS Up to 30 l/min
BK Up to 30 l/min
Buna standard
Buna, screw type override (Knob)
C0 Up to 45 l/min
CS Up to 45 l/min
CK Up to 45 l/min
PROPORTIONAL FLOW CONTROLS
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specic application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
Page 517