MECHANICAL FLOW CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DG-FDA FLOW DIVIDER / COMBINER VALVE, SPOOL TYPE
DESCRIPTION
10 size, 7/8-14 thread “Delta Series”, spool type, ow divider/combiner.
OPERATION
In the dividing mode, the DG-FDA will divert input ow from port (2) to ports (3) and (1), based on the ratio
specied, regardless of operating pressure. The DG-FDA will combine input ows from ports (3) and (1), to port
(2) by the same ratio. Should circuit operation result in a blockage of either (3) or (1), the opposite port may also
close under certain conditions. Should this potential exist, consult the factory.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
0
100
200
300
400
500
600
0 42 6
Pressure Drop (PSI)
0
5
10
15
Flow (GPM)
20
25
30
35
40
0 5 10 15 20
Pressure Drop (bar)
Flow (LPM)
3 6
0
100
200
300
20
400
64 8 10 12
Flow (GPM)
0
5
10
15
20
Pressure Drop (PSI)
0 01 20 03 4 0
Flow (LPM)
Pressure Drop (bar)
9 12
VALVE SPECIFICATIONS
Maximum Flow 12 GPM (45 LPM)
Accuracy on Flow Splits ±10% of Max Rated Inlet Flow
Maximum Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .21 lbs (.10 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Cavity DELTA 4W
Cavity Form Tool (Finishing) 40500002
Seal Kit 21191214
Actual Test Data (Cartridge Only)
PERFORMANCE
HYDRAULIC SYMBOL
DO NOT EXCEED MAXIMUM FLOW PER MODEL
For higher accuracy ow ratio, use DG-FDH.