SOLENOID OPERATED DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 44 / 12-2022
DF-S3T DIRECT ACTING SPOOL, 3 WAY 2 POSITION, TRANSMISSION & BRAKE
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, solenoid operated, 3 way 2 position, transmission & brake spool valve.
OPERATION
When de-energized the DF-S3T allows ow from (3) to (2) and blocks ow at port (1). When energized the valve
allows ow from (1) to (3) and blocks ow at port (2).
OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after
pulling knob out twist 180 degrees and release. The valve will remain in that position.
FEATURES
• Hardened parts for long life.
• Efcient wet-armature construction.
• Cartridges are voltage interchangeable.
• Manual override option.
• Industry common cavity.
• Unitized, molded coil design.
• Continuous duty rated solenoid.
• Optional coil voltages and terminations.
• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.
Nominal Flow 8 GPM (30 LPM)
Rated Operating Pressure 1500 PSI (103 bar)
Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .28 lbs (.12 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)
Cavity DELTA 3W
Cavity Tools Kit
(form tool, reamer, tap) 40500001
Seal Kit 21191204
VALVE SPECIFICATIONS
Actual Test Data (Cartridge Only)
0
50
100
0
150
2 4 6 8
0
Pressure Drop (PSI)
5
10
0
Flow (GPM)
5 10 15 20 25 30
Pressure Drop (bar)
Flow (LPM)
Port 1 to 3 (eng) Port 3 to 2 (de-eng)
PERFORMANCE
HYDRAULIC SYMBOL
Contamination Tolerant Product.
This valve is designed for transmission and brake
applications. Consult factory for alternate low
wattage coil options.
1
2
3