MECHANICAL FLOW CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
FLOW CONTROLS
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING:
The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
ORDERING INFORMATION
PP
-
FC
P
-
-
OPTIONS
BODIES
Standard, Buna
00
Blank Without Body
Standard, Viton
V
0
N
1/4 NPTF Ports
S
#6 SAE Ports
FLOW
SETTING
01.0
1.0 GPM
02.0
2.0 GPM
03.0
3.0 GPM
04.0
4.0 GPM
05.0
5.0 GPM
+/-15%
3/4-16 UNF-2A
THREAD
.22 [5.5]
2.82
[71.6]
1.61
[41.0]
2.50
[63.5]
1.25
[31.8]
#6 SAE PORT
(3X)
1.18
[29.9]
.63
[15.9]
.25 [6.3]
Ø.281 [7.1] (2X)
MTG. HOLE
1.13
[28.6]
1.17
[29.7]
.25 [6.4]
BODY WEIGHT: .56 lbs [.25 kg]
2.25
[57.2]
.58
[14.8]
2.25 [57.2]
1.75 [44.5]
DF-FCP FIXED PRIORITY FLOW CONTROL VALVE
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, xed priority ow control valve.
OPERATION
The DF-FCP allows pressure compensated ow from (3) to (1) regulated by the pressure present at (3). Excess
ow bypasses out (2). The spring chamber is constantly vented at (1).
FEATURES
Hardened parts for long life.
Industry common cavity.
DFFCP00
0
2
4
6
8
10
12
0 500 1000 1500 25002000 3000
0
Regulated Flow (GPM)
5
10
Pressure @ Port 1 (PSI)
15
20
25
30
35
40
45
0 50 100 150 200
Pressure @ Port 1 (bar)
5 gpm setting 10 gpm setting
0
2
4
6
8
10
12
0 500 20001000 1500 2500 3000
0
5
10
Regulated Flow (LPM)
Regulated Flow (GPM)
15
20
Pressure @ Port 2 (PSI)
25
30
35
40
45
0 50 100 200150
Regulated Flow (LPM)
Pressure @ Port 2 (bar)
10 gpm setting5 gpm setting
VALVE SPECIFICATIONS
Maximum Flow 10 GPM (38 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .26 lbs (.12 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Cavity DELTA 3W
Cavity Form Tool (Finishing) 40500001
Seal Kit 21191206
Actual Test Data (Cartridge Only)
PERFORMANCE
HYDRAULIC SYMBOL
1
2
3
MECHANICAL FLOW CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DIMENSIONS
ORDERING INFORMATION
Body Weight: .76 lbs (.35 kg)
DF-FCP – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 1/4” NPTF Ports
S #6 SAE Ports
FLOW SETTING
01.0 1 GPM
02.0 2 GPM
03.0 3 GPM
04.0 4 GPM
05.0 5 GPM
06.0 6 GPM
07.0 7 GPM
08.0 8 GPM
09.0 9 GPM
10.0 10 GPM
± 15%