MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DF-CPD PILOT TO CLOSE CHECK VALVE, GUIDED BALL
HYDRAULIC SYMBOL
PERFORMANCE VALVE SPECIFICATIONS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot to close, ball check valve.
OPERATION
The DF-CPD allows free ow from (3) to (2), and blocks ow from (2) to (3). Flow will be blocked from (3) to (2)
when sufcient pressure is applied at (1). The cartridge has various “pilot ratios” (see options).
Example: 1/4 for 4:1 of the load pressure held at (3) is required at (1) to close the valve. The check is spring
biased to assure holding in static or no-load conditions.
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Maximum Flow 10 GPM (38 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Typical Internal Leakage (150 SSU) 50 drops/min from (2) to (3)
5 drops/min from (3) to (2)
when port (1) is piloted
Pilot Ratio (see options)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .20 lbs (.09 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Cavity DELTA 3W
Cavity Form Tool (Finishing) 40500001
Seal Kit 21191202
Actual Test Data (Cartridge Only)
0
50
100
150
200
0
250
4 62 8 10 12
Flow (GPM)
0
5
10
15
0 5 10
Pressure Drop (PSI)
15 20 25 30 35 4540
Flow (LPM)
Pressure Drop (bar)
Port 3 to 2 (4:1) Port 3 to 2 (6:1)
Consult chart for ow operation of each model.
Special higher bias spring values available.
Consult factory.
MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DIMENSIONS
ORDERING INFORMATION
DF-CPD – – –
OPTIONS BODIES
Buna, 4:1 Ratio 04 Blank Without Body
Buna, 6:1 Ratio 06 N 1/4” NPTF Ports
Viton, 4:1 Ratio V4 S #6 SAE Ports
Viton, 6:1 Ratio V6
CRACK RESSURE
0015 15 PSI
0025 25 PSI
0050 50 PSI
0075 75 PSI
0100 100 PSI
± 10%
Body Weight: .76 lbs (.35 kg)