MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DF-CPB PILOT OPERATED CHECK VALVE, GUIDED BALL
HYDRAULIC SYMBOL
PERFORMANCE VALVE SPECIFICATIONS
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, pilot operated, ball check valve.
OPERATION
The DF-CPB allows free ow to pass from (2) to (1) and blocks ow from (1) to (2). When pilot pressure is applied
to port (3) the valve allows free ow from (1) to (2).
FEATURES
• Hardened parts for long life.
• Industry common cavity.
Nominal Flow 8 GPM (30 LTR/M) from (1) to (2)
5 GPM (19 LTR/M) from (2) to (1)
Rated Operating Pressure 3500 PSI (241 bar)
Typical Internal Leakage (150 SSU) 0-5 drops/min
Pilot Ratio 4:1
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .19 lbs (.09 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Cavity DELTA 3W
Cavity Form Tool (Finishing) 40500001
Seal Kit 21191202
Actual Test Data (Cartridge Only)
0
50
100
150
200
250
300
0 2 4 6 8 10 12
0
5
10
15
20
0 10 20 30 40
Free Flow 2 to 1 Piloted Open 1 to 2
Pressure Drop (PSI)
Flow (GPM)
Pressure Drop (bar)
Flow (LPM)
For sealed pilot piston consult factory.
0.030″ to 0.060″ diameter orice recommended
in the feed line to port #3.
MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DIMENSIONS
ORDERING INFORMATION
DF-CPB – – –
OPTIONS BODIES
Buna Standard 00 Blank Without Body
Viton Standard V0 N 3/8” NPTF Ports
S #6 SAE Ports
CRACK RESSURE
0025 25 PSI
± 10%