SOLENOID OPERATED DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 44 / 12-2022
DE-S2F PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED, SOFT SEAT
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, pilot operated soft seat poppet
valve with reverse ow de-energized.
OPERATION
When de-energized the DE-S2F blocks ow from (1) to (2) and allows reverse ow from (2) to (1). When energized
the valve allows ow from (1) to (2) but restricts reverse ow from (2) to (1).
OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after
pulling knob out twist 180 degrees and release. The valve will remain in that position.
FEATURES
• Soft seat for ultra low leakage.
• Efcient wet-armature construction.
• Cartridges are voltage interchangeable.
• Manual override option.
• Industry common cavity.
• Unitized, molded coil design.
• Continuous duty rated solenoid.
• Optional coil voltages and terminations.
• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.
Nominal Flow 10 GPM (38 LPM)
Rated Operating Pressure 1000 PSI (69 bar)
Typical Internal Leakage (150 SSU) Negligible
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range 32° to 160°F (0° to 70°C)
Weight .25 lbs (.11 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)
Cavity DELTA 2W
Cavity Tools Kit
(form tool, reamer, tap) 40500000
Seal Kit 21191200
VALVE SPECIFICATIONS
Actual Test Data (Cartridge Only)
0
50
100
150
200
0 5 10 15 20
Flow (GPM)
Pressure Drop (PSI)
0
5
10
0 25 50 75
Flow (LPM)
Port 1 to 2 (eng) Port 2 to 1 (de-eng)
Pressure Drop (bar)
Operational shift limit 10 GPM (38 LPM).
For shifted ow performance consult chart.
PERFORMANCE
HYDRAULIC SYMBOL
2
1