MECHANICAL FLOW CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, cartridge type, hand pump.
OPERATION
The DE-HPD hand pump when pipe handle is lifted, primes thru port (2) and when pushed provides ow pressure
to outlet port (1).
FEATURES
• Large displacement per stroke.
• Industry common cavity.
SPECIAL APPLICATION VALVES
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
DE-HPD Hand Pump, Push to Pump type
10 size, 7/8-14 thread, “Delta” series, cartridge type, hand pump.
The DE-HPD hand pump when pipe handle is lifted, primes thru port (2) and when pushed provides flow
pressure to outlet port (1).
Large displacement per stroke.
Industry common cavity.
This product is not intended as a load holding device.
Linkage is not to be removed.
24” Maximum handle length.
Typical Internal Leakage
(150 SSU)
36 to 3000 SSU (3 to 647 cSt)
Media Operating
Temperature Range
-40 to 250 F (-40 to 120 C)
General Purpose Hydraulic Fluid
Cartridge Torque
Requirements
Cavity Form Tool (Finishing)
Pump Effective Area .44 in
2
0
500
1000
1500
2000
0 20 40 60 80 100 120 140
Force (LBS)
With 12 inch long pipe handle
0
20
40
60
80
100
120
0 10 20 30 40 50 60
DE-HPD HAND PUMP, PUSH TO PUMP TYPE
Nominal Flow .39 cu in/stroke
Rated Operating Pressure 3000 PSI (207 bar)
Typical Internal Leakage
(150 SSU) 0-10 drops/min
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight 1.5 lbs (.69 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)
Cavity DELTA 2W
Cavity Form Tool (Finishing) 40500000
Seal Kit 21191200
VALVE SPECIFICATIONS
This product is not intended as a load holding
device. Linkage is not to be removed.
36” Maximum handle length.
HYDRAULIC SYMBOL
PERFORMANCE
Actual Test Data (Cartridge Only)
0
500
1000
1500
0
2000
20 40 60 80 140
0
20
40
60
Pressure (PSI)
80
100
120
0
Force (LBS)
With 12 inch long pipe handle
10 50 60
Force (kg)
20 30 40
Pressure (BAR)
100 120