4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 2-2023
DE-CVA DIRECT ACTING CHECK VALVE, POPPET
MECHANICAL DIRECTIONAL CONTROLS
MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
DE-CVA Direct Acting Check Valve, Poppet
10 size, 7/8-14 thread, “Delta” series, direct acting check valve.
The DE-CVA allows free flow passage from (2) to (1) and blocks flow from (1) to (2).
The cartridge has a fully guided check poppet which is spring-biased closed until sufficient pressure is
applied at (2) to open to (1).
• Hardened parts for long life and low leakage.
• Optional bias springs for backpressure application flexibility.
• Fully guided poppet assembly.
• Industry common cavity.
Drop-In pilot pistons can be used to create P.O. Check Valve
Function, see the “Accessories” section for details.
PERFORMANCE
Actual Test Data (Cartridge Only)
Typical Internal Leakage
(150 SSU)
0-5 drops/min
36 to 3000 SSU (3 to 647 cSt)
Media Operating
Temperature Range
-40° to 250° F (-40° to 120° C)
General Purpose Hydraulic Fluid
Cartridge Torque
Requirements
30 ft-lbs (40.6 Nm)
Cavity Form Tool (Finishing)