AJ-FCA Motorized Adjustable Pressure Compensated Flow Control
DESCRIPTION
16 size, 1 5/16 -12 thread, “Super” series, motorized adjustable pressure compensated flow control valve. A
screw-in, cartridge-style, adjustable orifice, pressure compensated, hydraulic flow regulating valve.
OPERATION
The AJ-FCA maintains a constant flow rate out of (1) regardless of load pressure changes in the circuit
downstream of (1).
The adjustable control orifice can be set to customer flow specification. (see options for ranges)
The valve begins to respond to load changes when the flow through the valve creates a pressure differential
across the control orifice greater than 100 PSI (6.9 bar), with accurate flow maintenance from 100 to 3500
PSI (6.9 to 240 bar).
Reverse flow (1) to (2) returns through the control orifice and is non-compensated.
FEATURES
Hardened parts for long life.
Industry common cavity.
Fine low-torque adjustment.
VALVE SPECIFICATIONS
Nominal Flow 25 GPM (95 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Note: When used as a bypass flow control in
applications. Where the priority flow port will be
blocked by external valving, bypass pressure drop
will increase unless a small amount of leakage is
provided for the priority port. Consult factory.
Filtration ISO 18/16/13
HYDRAULIC SYMBOL
Media Operating Temperature
Range
-40° to 250° F (-40° to 120° C)
Weight
2.12 lbs. (.96 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque
Requirements
90 ft-lbs (122 Nm)
Flow Range .25 to 25 GPM
Travel Time at Rated Voltage 18 sec Min to Max Setting
Power Requirements 5 Watts
Allowable Input Voltage 80% to 120% of Rated
Cavity SUPER 2W
Cavity Form Tool (Finishing)
40500017
PERFORMANCE
Seal Kit
21191400
Page 632
SPECIAL APPLICATION VALVES
Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
DIMENSIONS
ORDERING INFORMATION
AJ-FCA - - - -
OPTIONS BODIES
Buna Standard 00 Blank Without Body
N 3/4 NPT Ports
S # 12 SAE Ports
TERMINATION VOLTAGE
Dual Lead, 22” Long DL 12 12 VDC
Page 633