LE - 81
BC332375783111en-000101 • February 2020
Logic Elements Technical Information
PERFORMANCE CURVE
APPLICATION
SPECIFICATION
OPERATION
SCHEMATIC
144
108
72
0
psi
US gal/min
bar
9
6
L/min
Reverse Free Flow Pressure drop
33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
36
3
0
40
80
0
12
15
120
18
36
3 2
Flow
180
9
27
45
200
160
3 4
(2 blocked)
The CP312-6 is a 16-size, load sense, priority, static, pressure compensator. The
valve will provide on-demand priority ow to port 2 in the required amount
(dependent on the load sense pressure on port 1), allowing the excess ow to
go to auxiliary functions through port 4.
Rated pressure 210 bar [3045 psi]
Rated ow at 7 bar
[100 psi]
114 l/min
[30 US gal/min]
Weight 0.63 kg [1.39 lb]
Cavity CP16-4
PC16-LPS
Pressure Compensator
Common applications include steering circuits that require pre-compensated, priority
ow to go to the steering system, and the excess ow will go to an auxiliary function,
like a fan motor. To obtain dynamic load sensing (priority type pre-comp) add in orice
between ports 2 and 1 in the manifold. This provides faster response and is commonly
used in steering to ush out LS line. See Circuit Example.
Theoretical performance