For more than 40 years, Danfoss has been developing
state-of-the-art components and systems for mobile
machinery used in off-highway operations around the
world. We have become a preferred supplier by
offering the best of what really matters: The hardware
inside your vehicle application.
The MP1 motor is designed for use primarily in mobile
equipment using existing and proven technology.
These motors have been optimized with regard to
options, life, package size and installed cost.
The MP1 motor is a fixed displacement axial piston
motor and is intended for closed and open circuit
medium power applications. These motors are
designed primarily to be combined with other
products in closed and open circuit systems to
transfer and control hydraulic power.
The MP1 motors consists of two displacements in one
package size. Three different configurations are
available, an SAE A, B and cartridge style two-bolt
configuration.
Features
Wide Range of Options
Two displacements in a single package
SAE A, B, and cartridge style two-bolt
mounting configuration
Tapered shaft with shaft seal dust
protector for fan drive applications
Proven reliability and performance
Worldwide sales and service
Greater Total Efficiency
Increased motor efficiency
Expanded Functionality
PLUS+1
®
Compliant speed sensor
option
Integrated loop flushing valve option
Anti-cavitation and shock valve option
available
Machine Integration Benefits
Industry leading motor length
Metric and Inch O-ring boss system port
interfaces
Comprehensive technical literature is
online at www.danfoss.com
Data Sheet
MP1 Axial Piston Motors
Size 20/24
©
Danfoss | November 2019 AI300608691405en-000101 | 1
Technical Specification
Physical properties
Features Unit 20 24
Model Configuration Fixed
Displacement cm
3
[in
3
/rev] 20.0 [1.22] 24.0 [1.46]
Mass (Weight) dry kg [lb] 5.6 [12]
Operating parameters
Parameter Unit
20/24
Speed limit
Close Circuit
Rated
min
-1
(rpm)
4200
Maximum 4700
Open Circuit
Rated 3400
Maximum 3800
System pressure
Maximum working pressure
*
bar [psi]
350 [5000]
Maximum pressure
380 [5429]
Case pressure
Rated
bar [psi]
2 [29]
Maximum
6 [87]
*
Applied pressures above maximum working pressure requires Danfoss application approval.
Schematic
Closed Circuit
A
B
L2 N
L1
P400620
Open Circuit
A
B
L2 N
L1
CCW
P400648
Data Sheet
MP1 Axial Piston Motors Size 20/24
2 |
©
Danfoss | November 2019 AI300608691405en-000101
Dimensions
SAE-A
Case drain port “L1
Per ISO 11926-1 3/4-16
Per ISO 6149-1 M18x1.5
93 ± 1.5
93 ± 0.8
147 ± 1.2
(center of
speed sensor)
Paint free
49.5 ±0.8
(Center of
Drain port)
(Center of
Drain port)
Ø 95 ± 1.5
+ 0.3
- 0.1
2x Ø 11.1
53.2 ± 0.3 53.2 ± 0.3
65 ± 1.5
65 ± 1.5
49.5 ±0.8
(Center of
Drain port)
Case drain port “L1
Per ISO 11926-1 3/4-16
Per ISO 6149-1 M18x1.5
P400653
93 ± 0.8
2x 131 ± 1.2
System port “A
Per ISO 11926-1 7/8-14
Per ISO 6149-1 M22x1.5
12 ± 1
0
- 0.5
Mounting flange
Flange 82-2
Per ISO 3019-1 (SAE A)
6.4
0
- 0.05
Ø 82.55
30 ±0.530 ±0.5
49.5 ±0.8
System port “B
Per ISO 11926-1 7/8-14
Per ISO 6149-1 M22x1.5
59.5 ±0.8
(System
Ports)
57 ± 1.5
SAE-B
Case drain port “L1
Per ISO 11926-1 3/4-16
Per ISO 6149-1 M18x1.5
93 ± 0.8
147 ± 1.2
93 ± 1.5
(center of
speed sensor)
Paint free
49.5 ± 0.857 ± 1.5
(Center of
Drain port)
(Center of
Drain port)
Ø 120 ± 1.5
+ 0.3
- 0.1
2x Ø 14.3
73 ± 0.3 73 ± 0.3
87 ± 1.5
87 ± 1.5
49.5 ±0.8
(Center of
Drain port)
Case drain port “L1
Per ISO 11926-1 3/4-16
Per ISO 6149-1 M18x1.5
P400654
93 ± 0.8
2x 131 ± 1.2
12 ± 1
0
- 0.5
Mounting flange
Flange 101-2 (SAE B)
Per ISO 3019-1
9.7
0
- 0.05
Ø 101.6
30 ±0.530 ±0.5
49.5 ±0.8
System port “A
Per ISO 11926-1 7/8-14
System port “B
Per ISO 11926-1 7/8-14
Per ISO 6149-1 M22x1.5
Per ISO 6149-1 M22x1.5
59.5 ±0.8
(System
Ports)
Data Sheet
MP1 Axial Piston Motors Size 20/24
©
Danfoss | November 2019 AI300608691405en-000101 | 3
Dimensions
Cartridge Mount
Case drain port “L1
Port ISO 11926-1 3/4-16
Port ISO 6149-1 M18x1.5
86.7 ± 1.2
(center of
speed sensor)
Paint free
49.5 ±0.8
(Center of
Drain port)
(Center of
Drain port)
Ø 120 ± 1.5
+ 0.3
- 0.1
2x Ø 14.3
73 ± 0.3 73 ± 0.3
87 ± 1.5
87 ± 1.5
49.5 ±0.8
(Center of
59.5 ±0.8
(System
Ports)Drain Port)
Case drain port “L1
Per ISO 11926-1 3/4-16
Per ISO 6149-1 M18x1.5
P400655
32.7 ± 0.8
32.7 ± 0.8
32.7 ± 1.5
2x 70.7 ± 1.2
12 ± 1 66.7 ± 1.2
0
- 0.5
Mounting flange
Flange 82-2 (SAE A)
Per ISO 3019-1)
9.7
0
- 0.05
Ø 101.6
30 ±0.530 ±0.5
49.5 ±0.5
System port “
A
Per ISO 11926-1 7/8-14
System port “B
Per ISO 11926-1 7/8-14
Per ISO 6149-1 M22x1.5
Per ISO 6149-1 M22x1.5
57 ± 1.5
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
4 |
©
Danfoss | November 2019 AI300608691405en-000101