3
MBS 4050 - -
IC.PD.P20.F2.02/520B2266
Data sheet Pressure transmitters for heavy-duty applications, type MBS 4050
Ordering, Special versions
Measuring range Pressure connection
0 - 1 bar..................................
1 0 E B 0 8 ...........................................................................G ½ A (EN 837)
0 - 1.6 bar...............................
1 2 E C 0 4 .....................................................................................¼ -18 NPT
0 - 2.5 bar..............................
1 4 F A 1 2 ............................................DIN 3852/3, M18×1.5 - 6g, NBR
0 - 4 bar................................
1 6 F B 0 4 ...............................................................DIN 3852-G ¼ A, NBR
0 - 6 bar................................
1 8 F D 1 0
...........................................
9
⁄
16
-18 UNF-2A (SAE J514), NBR
0 - 10 bar...............................
2 0 Electrical connection
0 - 16 bar................................
2 2 Figures refer to plug and standard PIN configuration - see page 4
0 - 25 bar................................
2 4 1 ..............................................................................................Plug Pg 9 (EN175301-803)
0 - 40 bar................................
2 6 2 ....................................*) Plug, AMP Econoseal, J-series, male excl. female plug
0 - 60 bar...............................
2 8 3 ..........................................................................................................Screened cable, 2 m
0 - 100 bar.............................
3 0 4 ......................Plug AMP 173065, male flying leads 125 mm excl. female plug
0 - 160 bar.............................
3 2 5 ..........................................*) Plug, IEC 947-5-2, M12 x 1, male excl. female plug
0 - 250 bar.............................
3 4 6 ..........................................................................................Plug Pg 11 (EN 175301-803)
0 - 400 bar.............................
3 6
0 - 600 bar.............................
3 8 Output signal
1 ...............................................................................................................................................4-20 mA
Pressure reference
2 ..............................................................................................................................................0-5 V d.c.
Gauge (relative).........................................
1 3 ..............................................................................................................................................1-5 V d.c.
Absolute.......................................................
2 4 ...............................................................................................................................................1-6 V d.c
5 ............................................................................................................................................0-10 V d.c
Dimensions/combinations
Type code
1 2 3 4 5 6
EN175301-803,
Pg9
AMP
Econoseal
2 m screened cable
AMP 173065, male,
Flying leads, 125
mm
IEC 60947-5-2
4 pin M12×1
EN 175301-803,
Pg11
DIN 3852-G ¼ A NBR,
O-ring
DIN 3852/3 M18×1.5
- 6g
NBR, O-ring
G ½ A
(EN 837)
¼-18 NPT
9
⁄
16
-18 UNF-2A (SAE
J514)
NBR, O-ring
Type code
FB04 FA12 EB08 EC04 FD10
*) Gauge versions only available as
selased gauge versions
Preferred versions
Non-standard build-up combinations
may be selected. However, minimum
order quantities may apply. Please
contact your local Danfoss office for
further information or request on other