1CE90
Overcenter Valve, Standard, Direct Acting, Internal Drain, Port 3 Pilot
350 bar [5000 psi] • 90 l/min [24 US gpm]
DESCRIPTION AND OPERATION
This is a direct acting overcenter valve, which is a pilot assisted relief with a free flow check. With the relief valve set at approximately 1.3 times the
maximum load induced pressure, the valve will prevent flow from port 1 to 2. When pilot pressure is applied to port 3, the valve will meter the flow from
port 1 to 2, compensating for any change in pilot pressure due to over-running or unstable loads. Free flow takes place from port 2 to port 1 through
the check portion of the valve. These valves are ideal in most applications bringing stability, load holding, and hose failure protection when the valve is
mounted onto or into the actuator. The spring chamber is connected to the valve port 2, so any back pressure will increase the pilot pressure required to
keep the valve open and the pressure at which the valve will open as a relief valve. This is also available in a dual housing for bi-directional control.
SCHEMATIC
DIMENSIONS
mm [in]
PERFORMANCE CURVES
Pressure Drop
PERFORMANCE DATA
Rated pressure 350 bar [5000 psi]
Rated ow 90 l/min [24 US gpm]
Max total relief pressure 350 bar [5000 psi]
Max recommended load
pressure at max setting
270 bar [3900 psi]
Pilot Ratio 4:1, 8:1
Leakage 0.3 ml/min nominal [5 drops/min]
Weight 0.29 kg [0.63 lb]
Cavity A12336
Motion Control Valves
Flow - L/min
Pressure - psi
Pressure - bar
Flow - US gpm
0 25 50 75 100
0 6.5 13 19.5 26
600
500
400
300
200
100
0
42
35
28
21
14
7
0
Free ow
Piloted open
62.0
(2.44)
max
54.0
(2.13)
5.0 A/F
17.0 A/F
32.0 A/F
M27 x 1.5-6g
Pilot (3)
Valve (2)
Cyl (1)
33
8:1 Pilot Ratio
Turn CW to increase pressure setting and CCW to
decrease pressure setting.
Torque lock nut to 20-25 Nm [15-18 ft lbs]
Installation torque
60 Nm [44 ft. lbs]
4:1 Version
Pressure - psi
Pressure - bar
0 25 50 75 100
0 6.5 13 19.5 26
240
210
180
150
120
90
60
30
0
16
14
12
10
8
6
4
2
0
Free ow
Piloted open