Proportional Valves
Proportional Valves Catalog
PV - 58
11141718 • Rev AF • April 2015
ORDERING
INFORMATION
SPECIFICATIONS
DIMENSIONS
OPERATION
0.0 0.2 2.0
0
435
870
1305
1740
2175
2610
3045
30
0
60
90
120
150
180
210
Current, Amps (with 12 VDCcoil)
bar psi
210
150
70
25
0
1
2
3
4
5
6
024681012141618
4.84.23.73.22.62.11.61.00.50
87
73
58
44
29
15
0
L/min
US
gal/min
barpsi
at 5L/min [1.3 US gal/min] Flow Rate
Pressure vs. Current
26 cSt[123 SUS] hyd.oil@50 C[122° F]
Pressure Drop vs. Flow
2to1
0.4
0.6 0.8 1.21.0 1.4 1.81.6
26 cSt[123 SUS] hyd.oil@50 C[122° F]
50
104.4
[4.11]
27 mm
44-50 Nm
[32-37 lbf ft]
47.6
[1.87]
3
2
1
M22x1.5
26mm
3-5 Nm [26-44 lbf*in]
KIT P/N 173802188
XRP 06 - 70 - 12D -DE - EN - 00 -V
25 = 6-25 bar
50
[90-360 psi]
= 6-55 bar [90-800 psi]
70 = 5-75 bar [90-1100 psi]
150 = 8-155 bar [120-2200 psi]
210 = 9-210 bar [130-3100 psi]
0= P0ush control (Standard)
EN = Screw control
Seals
Setting range
Manual override
V =Viton
Omit = Buna-N
Voltage
00 = No coil
12D = 12VDC
24D = 24VDC
Te
rmination
Housing and portsHousing P/N
00 =No Housing No Housing
SE6S =AL, #6 SAE NCS06/3-SE-6S
SE8S =AL, #8 SAE NCS06/3-SE-8S
SE3/8 =AL, 3/8 BSP
NCS06/3-SE-3/8
SE1/2 =AL, 1/2 BSP
NCS06/3-SE-1/2
00 = No connectorDN
AJ = AMP Jr
= DIN 43650 (ISO 4400)
FL600 = Lead wires
DE = Deutsch
Seals
230000110
230000070
DN1 = “DN” w/Connector
This is a pilot-operated, proportional pressure reducing/relieving valve.
Rated pressure 315 bar [4500 psi]
Rated ow at 7 bar
[100 psi]
25 l/min
[7 US gal/min]
Weight 0.55 kg [1.21 lb]
Hysteresis 3% maximum
Threshold current 0 A (12 VDC coil)
0 A (24 VDC coil)
Maximum control
current
1.8 A (12 VDC coil)
0.9 A (24 VDC coil)
Cavity NCS06/3
Standard Coil M19P 22 Watt
Theoretical performance
Schematic
Cross-sectional view
XRP 06
mm in
Pressure Reducing/Relieving, Piloted, Normally Closed
XRP 06