Proportional Valves
Proportional Valves Catalog
Proportional Valves
Proportional Valves Catalog
Proportional Directional
PV - 16
11141718 • Rev AF • March 2015
ORDERING
INFORMATION
DIMENSIONS
OPERATION
APPLICATIONS
SPECIFICATIONS SCHEMATIC
PERFORMANCE CURVES
* Rated Pressure based on NFPA fatigue test standards (at 1 Million Cycles).
S2
S1
2
1
4
3
PSV12-34-02
This is a proportional, non-compensated, 3 position 4 way, directional ow
control solenoid valve, with closed-center spool.
This is an electro-proportional directional control using a 3-Position, 4-Way
design for directional control of hydraulic cylinders and motors. For load-
independent ow control, apply with a pressure compensator, like CP701-4
(see Example Circuit). Port 1 should be used as the tank port, with a
maximum back-pressure of 150 bar. The highest return ow coming from a
cylinder should be connected to Port 2.
Use the available Comatrol Adapter Block (CP12-4-D05 or CP12-4-
D05-PC) to help test and replace proportional CETOP D05 - available in
compensated or non-compensated.
Note: For optimal performance install with the solenoid valve below the
tank oil level in the horizontal position, reducing the chance for trapped air
in the valve.
Rated Pressure* 260 bar [3770 psi]
Rated Flow at 10 bar
[145 psi]
50 l/min
[13 US gal/min]
Weight including coil 1.2 kg [2.64 lbs]
Hysteresis <4%
Threshold current 0.25 A (12 VDC coil)
0.50 A (24 VDC coil)
Maximum control
current
1.8 A (12 VDC coil)
0.9 A (24 VDC coil)
Cavity CP12-4
Standard Coil M19 33 Watt
Shown with Deutsch
connector
Shown with DIN
connector
PSV12-34-02