420
BLN-10267 • 520L0939 • Aug 2013
REF 12C.400 page 01
SOLENOID OPERATED DIRECTIONAL VALVES POPPET TYPE
98
274
SIZE 04
NOMINAL PORT SIZE 6.5
MAX FLOW RATE
l/min 25
US gpm 6.5
MAX PRESSURE
bar 315
psi 4500
CAVITY NUMBER 00.95 081
CAVITY “FLUID CONTROLS” 3/4”-16UNF-2B
MAX. TIGHTENING TORQUE Nm 40
WEIGHT INCLUDING COIL Kg 0.230
Type EVH 041
Type EVH 041
VERSIONS
DIMENSIONS (mm)
TYPE
HYDRAULIC SYMBOLS
FUNCTIONS OBTAINED WITH SOLENOID MAX. FLOW RATE l/min MAX. PRESSURE bar
De-energized Energized Without filter With filter Without filter With filter
A1
 25 20 250 210
C1

25 20 315 210
E C1

25 20 210 210
E C1

25 20 315 210
(21 W)
MANUAL OVERRIDE
Only for version A1
plunger type control pushed to operate
For version C1 only screw type
control pulled to operate
MANUAL OVERRIDE E
CAVITY
Detail X
(Connector A) 70
(Connector C) 73
(Conn. A) 49.5
(Conn. A) 52.5
(Conn. C) 55.5
(Connector A) 76
(Connector C) 79
(Conn. C) 52.5
Only for version A1
Only for version A1
TWO WAY - TWO POSITION
Hexagon 20
Max tightening torque 5 Nm
Stroke 2.5
SAE 08/2
Type EVH 041/2
Cartridge Valves Legacy Product
Technical Information
EVH 041
421
BLN-10267 • 520L0939 • Aug 2013
REF 12C.400 page 02
CHARACTERISTIC OPERATING CURVES
98
275
TYP
Without filter With filter

A1
32
C1
21
E C1
21
E C1
(21W)
21
Measurements effected at 20°C ambient temperature with mineral oil having viscosity of 26 cSt at 50°C.
Power input to coil: 90% of nominal value; temperature: 50°C. Cartridges only.
PRESSURE DROP
TYP
Without filter With filter

A1
23
C1
13
E C1
43
E C1
(21W)
13
LIMITS OF APPLICATION
TYP
Open Close
A1
25 - 80 30 - 90
C1
25 - 70 35 - 100
E C1
25 - 70 35 - 100
E C1
(21W)
25 - 70 35 - 100
RESPONSE TIMES (m. sec)
EXAMPLE OF ORDER DESIGNATION EVH 041
EVH 041 / E C1 - F - W - 24C - A - 00 - V
EVH 041 / E C1 - F - W - 24C - A - 00 - V
TYPE
SIZE
Refer to 2.950 for coils type and special voltages
OVERRIDE
Ignore if not required
VERSIONS
A1 - C1
300µ FILTER
Ignore if not required
W = Coil 21 W
(Available for “E C1” version only)
Ignore for standard version
SEALS
V = Viton seals
Ignore for normal seals
00 = Cartridge only
STANDARD COIL AND CONNECTOR (DIN43650)
00-00 = without coil and connector
12C-A = 12 V DC coil with type A connector
24C-A = 24 V DC coil with type A connector
48C-A = 48 V DC coil with type A connector
24A-C = 21 V DC coil with type C connector
48A-C = 42 V DC coil with type C connector
110A-C = 96 V DC coil with type C connector
220A-C = 194 V DC coil with type C connector
SPARE PARTS
Set of standard type external seals with back-up washers (Packs of minimum 10 sets)
EVH 041 = 230.00.023.0
HOUSING
Cartridge Valves Legacy Product
Technical Information
EVH 041