High performance directional v alve, ISO size 05
Solenoid controlled, 2-stage
Series WEVDE ...
Reference: 400--P--185110--EN--Aa/09.15
1/4 430.20.60.90
Replaces: W--30.40A
Classification:
S 315 bar, 160 l/min
S High switching reliability thanks to
2--stage follower spool operation
S Unaffected by:
-- asymmetric flow paths
-- long periods under high pressure
without switching
-- large pressure drops across the
spool lands
-- low supply voltage
S High flow rates
S Good ∆p -- Q characteristics
S Pressure in P, A and B to 315 bar
S Wet armature design, change coils
without opening hydraulic envelope
S With manual override
S Mounting interface to ISO 4401 /
CETOP R35H size 5, NFPA D05,
DIN 24 340 A10
1. Description
Series WEVDE ... -- 10 high performance
spool valves are internally piloted and
use the follower spool principle. The
main valve components are a cast
body, a spring-- centered follower spool
assembly and wet ar mature s olenoids
with pressure--tight core tube and
slip-- on coil. These v alves provide reli-
able service even under the severest
operating conditions such as very high
flow rates, high operating pressures,
supply voltage drops, long periods
without switching, large and sudden
changes in fluid temperature etc. The
highly effective spool actuation method
combines the advantages of direct act-
ing and two--stage solenoid valves,
without incurring the well known disad-
vantages of either type. The main spool
is offset by both the solenoid force and
the P ⇒ T *) pressure difference inside
the valve. The greater the P ⇒ Tpres-
sure difference, the greater the offset-
ting force. The spool is returned to the
mid--position in the same way, usingthe
P ⇒ T pressure difference and without
the need for the usual heavy centering
springs. If very low flow rates, or an
open circuit condition, result in there
being no P ⇒ T pressure difference,
then the spool actuaction reverts to the
normal solenoid / centering spring ar-
rangement.
*) The pressure in P must always be
equal to, or greater than, that in T and
the valve must be connected in the
conventional manner i.e. pressure to P,
Ttotank.
2. Symbols
1
WEVDE--42--A--10 WEVDE--42--AD--10
WEVDE--42--AG--10
WEVDE--42--BD--10
WEVDE--42--BG--10
WEVDE--43--D--10
WEVDE--43--G--10
A
B
PT
a
AB
PT
b
A
B
PT
a
A
B
PT
b
AB
PT
ba
WEVDE--42--B--10
A
B
PT
a
AB
PT
b
A
B
PT
ba
WEVDE--42--AH--10 WEVDE--42--BH--10 WEVDE--43--H--10
AB
PT
a
AB
PT
b
AB
PT
ba
WEVDE--42--AJ--10 WEVDE--42--BJ--10 WEVDE--43--J--10
AB
PT
a
AB
PT
b
A
B
PT
ba
2
3
4
8
7
9
10 16 22
14
15
20
21
13 19
4/2 FUNCTIONS
4/2 FUNCTIONS
WITH 4/3 SPOOLS
4/2 FUNCTIONS
WITH 4/3 SPOOLS
4/3 FUNCTIONS
Crossover transients