Solenoid Operated Spool Valve, ISO size 5
Direct Acting, Soft Switching
Series WEDEU ...
Reference: 400--P--185310--EN--A/09.15
1/4 430.20.60.81
Replaces: W--31.20A
Classification:
S 315 bar, 100 l/min
S Switching time is steplessly variable
from outside the valve
S Full adjustment range is 150 ... 1500
ms
S Special opening geometry, high s wit-
ching performance
S High flow rates
S Good ∆p -- Q values: no narrowing of
flow paths in energised position
S Slip-- on coils: coils can be changed
without opening the hydraulic enve-
lope
S Pressures to 315 bar in P, A and B
S Mounting interface to ISO 4401 /
CETOP R35H size 5, NFPA D05,
DIN 24 340 A10
A
B
Solenoid b
Solenoid a
PT
1. Description
Series WEDEU ...-- 10 solenoid oper-
ated spool valves are direct acting units
that provide smooth, shock --free accel-
eration, deceleration and reversal of
hydraulic cylinders and motors. The
design incorporates low--cost ramp
controls that are entirely hydraulic in
operation. The principal components
of the valve are a cast body, a control
spool with centering springs, and wet
armature solenoids with high--pressure
core tubes and slip--on coils (DC only).
A coil can be replaced, or the voltage
changed, without opening the hy-
draulic envelope. The valve switching
time is adjusted by means of a flow--
control s crew that is accessible from
the outside of the valve. The effect of
the throttle is to reduce the rate of oil
transfer between the two spring
chambers. This, in turn, dictates the
speed at which the spool shifts. To en-
sure that the spring chambers are
purged of air and completely filled with
oil when the valve is commissioned, it
must be operated through 6 ... 12 com-
plete cycles (spool stroked end -- to --
end) with the flow control screw turned
fully open. After this has been done, the
flow control needle can then be
screwed in half a turn at a time (2 mm
Allen key required) until the required
switching time is attained. Warning:the
flow control must never be screwed in
fully i.e. until it ”bottoms” -- this would
prevent any transfer of oil and the valve
would no longer function. The system
design must ensure that air cannot be
sucked back through the tank line. To
provide a r eliable oil supply to the two
spring chambers, the minimum tank
line back pressure should be 1 bar.
2. Symbols
1
WEDEU--42--A--10 WEDEU--42--AD--10
WEDEU--42--AG--10
WEDEU--42--BD--10
WEDEU--42--BG--10
WEDEU--43--D--10
WEDEU--43--G--10
A
B
PT
a
AB
PT
b
A
B
PT
a
AB
PT
b
AB
PT
ba
WEDEU--42--B--10
AB
PT
a
AB
PT
b
AB
PT
ba
WEDEU--42--AH--10 WEDEU--42--BH--10 WEDEU--43--H--10
AB
PT
a
AB
PT
b
A
B
PT
ba
WEDEU--42--AJ--10 WEDEU--42--BJ--10 WEDEU--43--J--10
AB
PT
a
A B
PT
b
AB
PT
ba
2
3
4
5
8
7
9
10
11
16
17
22
23
14
15
20
21
13 19
AB
PT
b
WEDEU--42--B--10
AB
PT
b
WEDEU--42--AN--10
AB
PT
a
WEDEU--42--AGG--10 WEDEU--42--BGG--10
AB
PT
b
AB
PT
WEDEU--43--GG--10
ba
Crossover transients
4/2 FUNCTIONS
4/2 FUNCTIONS
WITH 4/3 SPOOLS
4/2 FUNCTIONS
WITH 4/3 SPOOLS
4/3 FUNCTIONS