TYPE "L" COIL
TYPE "L" COIL
SEE PAGE
SEE PAGE
10-001.2
10-001.2
2
1
2
1
0.15
0.15
0.30
0.30
0.60
0.60
0.90
0.90
1.20
1.20
0.45
0.45
0.75
0.75
1.05
1.05
0.90
0.90
1.50
1.50
2.10
2.10
AMPERAGE (AMPS) @ 24 VDC
AMPERAGE (AMPS) @ 24 VDC
AMPERAGE (AMPS) @ 12 VDC
AMPERAGE (AMPS) @ 12 VDC
2.40
2.40
1.80
1.80
1.20
1.20
0.60
0.60
0.30
0.30
24
24
18
18
12
12
06
06
GPM
GPM
L/M
L/M
[121,9]
[121,9]
4.80"
4.80"
( SCREW TYPE )
( SCREW TYPE )
MANUAL OVERRIDE
MANUAL OVERRIDE
[45.2]
[45.2]
1.78"
1.78"
[76,2]
[76,2]
3.00"
3.00"
[76,2]
[76,2]
3.00"
3.00"
30
30
114
114
91
91
68
68
46
46
23
23
1.312"-12 UNF THD.
1.312"-12 UNF THD.
[45.7]
[45.7]
1.80"
1.80"
[104,1]
[104,1]
4.10"
4.10"
1.50" [38,1] HEX
1.50" [38,1] HEX
REGULATED FLOW (1-2) @ 160 PSI P
REGULATED FLOW (1-2) @ 160 PSI P
CLOSED
CLOSED
NORMALLY
NORMALLY
OPEN
OPEN
NORMALLY
NORMALLY
1
2
2
1
UL approved coil, IP68 and IP69K rated
UL approved coil, IP68 and IP69K rated
when used with waterproof connector.
when used with waterproof connector.
R
L
T
B
G
W
D
M
TERMINALS
TERMINALS
=18GA. 24" LEADS
=18GA. 24" LEADS
=SPADE TERM.
=SPADE TERM.
=BOLT TERM.
=BOLT TERM.
=DIN43650
=DIN43650
=WEATHER-PACK
=WEATHER-PACK
=DEUTSCH-DT04-2P
=DEUTSCH-DT04-2P
=METRI-PACK CONN.
=METRI-PACK CONN.
12D
12D
24D
24D
VOLTAGE
VOLTAGE
= 12 VDC
= 12 VDC
= 24 VDC
= 24 VDC
= BUNA "N"
= BUNA "N"
= VITON
= VITON
SEALS
SEALS
N
V
SIZE
SIZE
16 = 1.312"-12UNF
16 = 1.312"-12UNF
PORTS
PORTS
0
06BX
06BX
08BX
08BX
12TX
12TX
16TX
16TX
= CARTRIDGE ONLY
= CARTRIDGE ONLY
= G 3/4" BSPP
= G 3/4" BSPP
= G 1" BSPP
= G 1" BSPP
= SAE - #12
= SAE - #12
= SAE - #16
= SAE - #16
REGULATED FLOW
REGULATED FLOW
06
06
12
12
18
18
24
24
30
30
= 0 TO 6.0 GPM
= 0 TO 6.0 GPM
= 0 TO 12.0 GPM
= 0 TO 12.0 GPM
= 0 TO 18.0 GPM
= 0 TO 18.0 GPM
= 0 TO 24.0 GPM
= 0 TO 24.0 GPM
= 0 TO 30.0 GPM
= 0 TO 30.0 GPM
BASIC
BASIC
STYLE
STYLE
C
O
"A" = ALUM. HOUSING
"A" = ALUM. HOUSING
"S" = STEEL HOUSING
"S" = STEEL HOUSING
= NONE
= NONE
= MANUAL OVERRIDE
= MANUAL OVERRIDE
ADJUSTMENT OPTIONS
ADJUSTMENT OPTIONS
O
M
AMPS
AMPS
3.00
3.00
1.50
1.50
= NORMALLY CLOSED
= NORMALLY CLOSED
= NORMALLY OPEN
= NORMALLY OPEN
PFCV-16-X-X-XX-X-X-XXX X
PFCV-16-X-X-XX-X-X-XXX X
IN-LINE, NON-COMPENSATED FLOW CONTROL VALVE.
IN-LINE, NON-COMPENSATED FLOW CONTROL VALVE.
PROPORTIONAL, NORMALLY CLOSED OR NORMALLY OPEN,
PROPORTIONAL, NORMALLY CLOSED OR NORMALLY OPEN,
Steel = 95/100 Ft-Lb. [129/136 Nm]
Steel = 95/100 Ft-Lb. [129/136 Nm]
TORQUE:
TORQUE:
Aluminum = 70/75 Ft-Lb. [95/102 Nm]
Aluminum = 70/75 Ft-Lb. [95/102 Nm]
Reference: 520-P-112040-EN-01/10.2019
PFCV-16
DESCRIPTION
DESCRIPTION
OPERATIONS
OPERATIONS
FEATURES AND BENEFITS
FEATURES AND BENEFITS
Flow is proportional to the current input.
Flow is proportional to the current input.
Normally Open 36.0 to 0 GPM [137,0 to 0 L/m] @ 160 PSI DELTA P.
Normally Open 36.0 to 0 GPM [137,0 to 0 L/m] @ 160 PSI DELTA P.
Regulated flow Normally Closed 0 to 36.0 GPM [0 to 137,0 L/M] max.
Regulated flow Normally Closed 0 to 36.0 GPM [0 to 137,0 L/M] max.
in-line (RESTRICTIVE) type, hydraulic non-compensated flow control.
in-line (RESTRICTIVE) type, hydraulic non-compensated flow control.
This valve is a cartridge style, electro-hydraulic, proportional,
This valve is a cartridge style, electro-hydraulic, proportional,
ON THE VALVE VERSION.
ON THE VALVE VERSION.
IN THE EVENT OF POWER FAILURE THE VALVE WILL CLOSE OR OPEN DEPENDING
IN THE EVENT OF POWER FAILURE THE VALVE WILL CLOSE OR OPEN DEPENDING
increase or decrease proportionally.
increase or decrease proportionally.
When current is increased or decreased to the coil the flow will
When current is increased or decreased to the coil the flow will
position against a precision bias spring varying the flow.
position against a precision bias spring varying the flow.
energized the armature moves the metering orifice to open or to closed
energized the armature moves the metering orifice to open or to closed
portional, non-compensated, flow control valve. When the coil is
portional, non-compensated, flow control valve. When the coil is
This unit is a direct acting (NO PILOT FLOW), electro-hydraulic, pro-
This unit is a direct acting (NO PILOT FLOW), electro-hydraulic, pro-
Industry common cavity.
Industry common cavity.
All cartridge valves are 100% functionally tested.
All cartridge valves are 100% functionally tested.
All external carbon steel parts are plated for longer life against the elements.
All external carbon steel parts are plated for longer life against the elements.
Very efficient wet - armature solenoid core tube construction.
Very efficient wet - armature solenoid core tube construction.
Hardened precision fitted spool & sleeve provides reliable, long life.
Hardened precision fitted spool & sleeve provides reliable, long life.
Interchangeable solenoid coils & terminations options available.
Interchangeable solenoid coils & terminations options available.
Continuous-duty, very low heat rise & waterproof solenoid coil.
Continuous-duty, very low heat rise & waterproof solenoid coil.
PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE.
PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE.
Reference: 520-P-112040-EN-01/10.2019
PFCV-16
SPECIFICATIONS
SPECIFICATIONS
VALVE CAVITY: #C1620, See Page 0-014.0.
VALVE CAVITY: #C1620, See Page 0-014.0.
4.65 lbs [2,10 kg] steel body.
4.65 lbs [2,10 kg] steel body.
1.25 lbs [0,57 kg] aluminum body.
1.25 lbs [0,57 kg] aluminum body.
1.09 lbs [0,50 kg] coil & housing.
1.09 lbs [0,50 kg] coil & housing.
WEIGHT: 0.95 lbs [0,42 kg] cartridge only.
WEIGHT: 0.95 lbs [0,42 kg] cartridge only.
SKV-1622 Viton
SKV-1622 Viton
SEAL KIT: SKN-1622 Buna "N"
SEAL KIT: SKN-1622 Buna "N"
24 VDC, Operating current 0.2 to 1.2 AMPS.
24 VDC, Operating current 0.2 to 1.2 AMPS.
POWER REQUIREMENTS: 12 VDC, Operating current 0.4 to 2.4 AMPS.
POWER REQUIREMENTS: 12 VDC, Operating current 0.4 to 2.4 AMPS.
current control and a 50 Hz dither.
current control and a 50 Hz dither.
RESPONSE: The most efficient method to control this valve is with
RESPONSE: The most efficient method to control this valve is with
INTERNAL LEAKAGE: 40 cu.in/min [660 cc/m] @ 160 PSI DELTA P [11 Bar]
INTERNAL LEAKAGE: 40 cu.in/min [660 cc/m] @ 160 PSI DELTA P [11 Bar]
REGULATED FLOW: 36.0 GPM [136,0 l/m] Max. See performance chart.
REGULATED FLOW: 36.0 GPM [136,0 l/m] Max. See performance chart.
PROOF PRESSURE: 10,000 PSI [700 Bar]
PROOF PRESSURE: 10,000 PSI [700 Bar]
OPERATING PRESSURE: 5,000 PSI [350 Bar]
OPERATING PRESSURE: 5,000 PSI [350 Bar]
INSTALLATION: Flow 1-2 preferred, Max Flow 2-1 lower than shown on
INSTALLATION: Flow 1-2 preferred, Max Flow 2-1 lower than shown on
graph. Use undercuts in cavity to obtain max rated flow when using a
graph. Use undercuts in cavity to obtain max rated flow when using a
pressure compensator in series. Pressure drop across valve must not
pressure compensator in series. Pressure drop across valve must not
exceed 300 PSI [21] bar.
exceed 300 PSI [21] bar.
PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE.
PROPORTIONAL, IN-LINE TYPE, FLOW CONTROL VALVE.
MIL-H-5606, SAE-#10, SAE-#20, etc.
MIL-H-5606, SAE-#10, SAE-#20, etc.
OPERATING MEDIA: All general purpose hydraulic fluids such as
OPERATING MEDIA: All general purpose hydraulic fluids such as
OPERATING TEMPERATURE: -40° to +250° F. [-40° to +120° C.]
OPERATING TEMPERATURE: -40° to +250° F. [-40° to +120° C.]
5000 PSI [350 Bar] = Steel - Unplated.
5000 PSI [350 Bar] = Steel - Unplated.
VALVE HOUSINGS: 2500 PSI [175 Bar] = Aluminum - Anodized.
VALVE HOUSINGS: 2500 PSI [175 Bar] = Aluminum - Anodized.
info.el@bucherhydraulics.com www.bucherhydraulics.com/commoncavity
2015 by Bucher Hydraulics, Inc., 2545 Northwest Parkway, Elgin, Illinois 60124, USA
All rights reserved.
The technical information in this catalog, may contain calculated figures (for reference only) and not actual performance data for this product.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense.
The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to
continual improvement, we reserve the right to amend the product specifications contained in this catalogue.
©
Reference: 520-P-112040-EN-01/10.2019
PFCV-16