300-P-185310-EN-03/09.2024
Series WEDEU
3/5
4 Performance graphs
measured with oil viscosity 33 mm
2
/s (cSt)
20 100
2
10
40 60 80
4
6
8
12
A- / B spools
D spool
G spool
H spool
A ⇒ T
B ⇒ T
P
⇒
T
P ⇒ A
P ⇒ B
3356
-- -- 5 6
-- -- -- --
10 30 50 70
50
100
150
350
20 40 60 80
7
6
5
4
3
2
1
250
300
200
90 100
2245
3367
1167
Solenoid
OFF
ON
--
--
--
--
3
--
t
U
23 56
41
0 VDC
D Solenoid force: = ± 15 % voltage variation
= ± 50 % switching time
D Cold / hot solenoid: = ± 20 % switching time
D Flow rate Q (l/min): = influences values 3 + 6
(lower Q = shorter t)
D Pressure diff. Δp (bar): = ± 75 % change in Δp
= ± 10 % switching time
→ Q (l/min)
→ Q (l/min)
→ Δp (bar)
→ Δp (bar)
Δp-Q characteristics
Application limits
he quoted maximum flow rates apply when
he flows passing through the valve are equal
n both directions (symmetrical). For non-
ymmetrical flows, the maximum rates are
ubstantially reduced, in worst cases to only
1/3 of the above values.
The values 1 and 4 are jointly controlled by the setting of the
flow control, but it is usually the case that they are not equal.
Both values normally fall in the range 150 ... 1,500 ms. The
switching times are also strongly influenced by the following
factors
:
There are a large number of factors that cannot easily be
pre-determined. This means that the flow control cannot be
factory-set and adjustment on-site is therefore essential.
This is simple in practice, thanks to the externally-accessible
flow control.
OFF
ON
Switching times
1 = total energising time
2 = time until flow paths begin to open
3 = time for solenoid to open spool fully
4 = total spring-return time
5 = time until flow paths begin to close
6 = time for spring to close spool fully
5 Installation information
ATTENTION!
All installation and servicing must be carried out
with care, and by qualified personnel only. When
servicing valves (cleaning, changing seals, etc.)
note the following:
A (and B) spools must not be reversed, or the
function P ⇒ A / B ⇒ T will become P ⇒ B / A ⇒
T (and vice versa). All other spools are symmetri
cal but should always be reassembled with their
original orientation, in any case.
IMPORTANT!: When changing seals, the new
seals should be thoroughly oiled or greased be
fore fitting them to the valve.
IMPORTANT!: Use the correct tightening torque
when fitting Spring cap, DC and Core tube.
IMPORTANT!: At installation, be sure to mount
the valve with its hydraulic ports mating with those
of the manifold block or subplate and, finally, use
the correct tightening torque for the 4 x M6 moun
ting screws.