7. Installation and servicing
All installation and servicing must be
carried out with care, and by qualified
personnel only. The following points
must be observed: ”A”(and ”B”)spools
must not be reversed, or the function
P⇒A/B⇒T will become P⇒B/A⇒T
(and vice versa for ”B”). All other spools
are symmetrical, but should always be
reassembled with their original orienta-
tion, in any case. When changing
seals, the new seals must be thor-
oughly oiled or greased before they are
fitted. Use the specified tightening
torques when fitting the spring cap, DC
and the core tube. At installation, make
sure that the valve interface aligns with
the interface of the mating surface, and
use the specified tightening torque
when fitting the valve mounting bolts.
8. Model code key
WEDE
43-- -- D -- 1 0 -- V -- 1 24 VDC
Direct solenoid operated directional valve
42
43
A
AN
B
BN
AD / AG / AH / AJ / AGG
BD / BG / BH / BJ / BGG
D/G/H/J/GG
10
V
Special seals by arrangement
1 ... 9
Voltage and current plainly specified
=
=
=
=
=
=
=
=
=
=
=
=
4/2 function with 4/3 spool,
solenoid at a--end
4/2 function with 4/3 spool,
solenoid at b--end
4/3 function
4/2 function
4/3 function
4/2 function, overlap X--over
4/2 function, underlap X--over
nominal size 10 mm (ISO size 5 interface)
Viton seals (Standard)
design number (omit when ordering new units)
4/2 function, overlap X--over
4/2 function, underlap X--over
9. Related data sheets
Old no. New no.
i--41 400-- P-- 050101-- E DIN 24 340 size A10 interface
E 2015 by Bucher Hydraulics AG Frutigen, CH-3714 Frutigen
www.bucherhydraulics.cominfo.ch@bucherhydraulics.com
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.