400-P-180120-EN-02/09.2024
Series WEDC…
2/5
3 Technical data
General characteristics Description, value, unit
Designation 4/3 and 4/2 directional spool valves
Design manifold mounting, direct acting, electrically operated
Mounting method 4 mounting holes for M5x40 mounting bolts
(valve mounting bolts supplied with the valve)
Tightening torque 5.2 Nm ± 5%
Size size 02 interface to ISO 4401-02-01
Weight - valve with one solenoid
- valve with two solenoids
0.90 kg
1.30kg
Mounting attitude unrestricted
Ambient temperature range -30 °C … +80 °C
Hydraulic characteristics Description, value, unit
Maximum operating pressure - ports A, B, P
- port T
250bar
160bar (static 250bar)
Maximum flow rate 25 l/min
Flow direction see table “Symbols / Spool types”
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
HEES biodegradable fluids;
for other fluids, please consult BUCHER
Hydraulic fluid temperature range -30°C … +80°C
Viscosity range 10…500mm
2
/s (cSt), recommended 15...250mm
2
/s (cSt)
Minimum fluid cleanliness
Cleanliness class to ISO 4406:1999
class 20/18/15
Electrical characteristics Description, value, unit
Supply voltage 12V DC, 24V DC / 115V AC, 230V AC (50…60Hz)
Supply voltage tolerance ±10%
Nominal power consumption V DC = 27 W / V AC = 25 W
Switching time 15 … 80 ms (energizing)
10 … 40 ms (de-energizing)
Depending on pressure, flow rate, pressure drop and viscosity as well as
dwell time under pressure, the switching times may vary from the the stated
values.
Relative duty cycle 100%
Protection class to ISO20653 / EN60529 IP 65 / IP 67 / IP 69K, see “Ordering code”
(with appropriate mating connector and
proper fitting and sealing)
Electrical connection DIN EN 175301-803, 3-pin 2 P+E (standard)
for other connectors, see “Ordering code”