Type series: W1F_B… (installation deep)
Reference: 400-P-110120-EN-01/03.2023
- Slip-in cartridge valve
- For cavity AD
- All external parts with zinc-nickel plating according to
DIN EN ISO 19598
- Guided valve spool and poppet
- With or without manual override
- As an option, hand lever can be tted to solenoid
- De-energized closed
- The slip-on coil can be rotated, and it can be replaced
without opening the hydraulic envelope
- High pressure wet-armature solenoids
- Various plug-connector systems and voltages are
available
Directional valve
3-way/2-position
Q
max
= 40 l/min, p
max
= 315 bar
switching solenoid, direct acting, poppet type
Type series: W1F_B… (installation deep)
Description
The 3-way/2-position solenoid-operated directional
seat valves, series W1F_B (installation deep), are size
6, direct acting, and pressure balanced screw-in valves.
They are designed on the tried and tested principle of
the guided poppet, and the guide spool has a seal.
This valve type has an overlapped spool. In the cros-
sover position, all connections are thus disconnected,
i.e., there is no connection between ports 1, 2, and 3
during the valve’s switching period, with the result that
only a minimal loss of the ow/pressure occurs. This
type is the "deep" installation version, which ts into
the cavity type according to the AD factory standard.
For the "shallow" installation version, see separate
data sheet. These cartridge seat valves are also avai-
lable with or without manual override, and with the
option of an additional hand lever. All external parts of
the cartridge are zinc-nickel plated, and are thus sui-
table for use in the harshest operating environments.
The slip-on coils can be replaced without opening the
hydraulic envelope and can be positioned at any ang-
le through 360°. These valves are predominantly used
in certain mobile and industrial applications where le-
ak-tight shut-o functions are crucially important. Ex-
amples are where loads, tensions, or clamping forces
must be held without leakage. For self-assembly, plea-
se refer to the section related data sheets.
Symbol
13
2
Without manual override (standard)
13
2
With manual override
2/6
Type series: W1F_B… (installation deep)
Reference: 400-P-110120-EN-01/03.2023
Technical data
General characteristics Description, value, unit
Function group Directional valve
Function 3-way/2-position
Design Slip-in cartridge valve
Controls switching solenoid
Characteristic direct acting, poppet type
Transition/central position of spool/piston zero or overlap/positive (closed)
MTTFd value 150 years
Construction size NG 6
Mounting attitude unrestricted
Weight 0.85 kg
Cavity acc. factory standard For cavity AD
Tightening torque steel 5.2 Nm
Tightening torque aluminium 5.2 Nm
Tightening torque tolerance ± 5 %
Minimum ambient temperature - 25 °C
Maximum ambient temperature + 50 °C
Surface protection
All external parts with zinc-nickel plating according to DIN EN
ISO 19598
Sealing material see ordering code
Seal kit order number NBR: DS-095-N / FKM: DS-095-V
IMPORTANT!
The less favorable values from the general, hy-
draulic and electrical characteristics determi-
ne the temperature range of the whole valve.
Hydraulic characteristics Description, value, unit
Maximum operating pressure 315 bar
Maximum ow rate 40 l/min
Flow direction see symbol
Hydraulic uid
HL and HLP mineral oil according to DIN 51 524; other uids
on request!
Minimum uid temperature - 25 °C
Maximum uid temperature + 80 °C
Viscosity range 10 … 500 mm²/s (cSt)
Recommended viscosity range 15 … 250 mm²/s (cSt)
Minimum uid cleanliness (cleanlineless class according to ISO
4406:1999)
class 20/18/15
3/6
Type series: W1F_B… (installation deep)
Reference: 400-P-110120-EN-01/03.2023
Electric characteristics Description, value, unit
Actuator type solenoid coil
Solenoid coils type D45/207
Supply voltage DC 12/24 V DC
Supply voltage AC 115/230 (50 … 60 Hz) V AC
Supply voltage tolerance ± 10 %
Maximum permissible power consumption V DC = 30 ... 32 W / V AC = 31 ... 32 W
Switching time
Flow direction 1 to 2: 30 ... 180 ms ( energizing), 10 ... 80 ms
(de-energizing) / Flow direction 3 to 2: 25 ... 120 ms ( energi-
zing), 10 ... 90 ms (de-energizing)
Relative duty cycle 100 %
Electrical connection coil several connection types available, see ordering code
Protection class solenoid coil to ISO 20 653 / EN 60 529
several classes of protection available, see ordering code (with
appropriate mating connector and proper tting and sealing)
IMPORTANT!
To ensure the performance data is not com-
promised, it is imperative to use coils D45/207
according to data sheet 400-P-120120.
NOTE!
These times are strongly inuenced by
uid pressure, ow rate and viscosity, as
well as by the dwell time under pressure.
Performance graphs
measured with oil viscosity 33.0 mm²/s (cSt), coil at steady-state temperature and 10 % undervoltage
p = f (Q) Performance limit Δp = f (Q) Pressure drop-ow rate characteristic
400-PG-0420
0
50 (700)
100 (1400)
150 (2100)
200 (2900)
250 (3600)
300 (4300)
350 (5000)
Q [l/min (gpm)]
403020100
p [bar (psi)]
(10)
(7.5)(5)(2.5)
1) = 1 →2, 2 → 1, 2 → 3
1)
2)
2) = 3 → 2
400-PG-0419
0
10 (140)
20 (285)
30 (430)
40 (570)
Q [l/min (gpm)]
40
200
p [bar (psi)]
10 30
(10)
(5)(2.5
)(
7.5)
1) = 2 → 1; 2 → 3
2) = 1 → 2
3) = 3 → 2
1)1)
2)2)
3)3)
4/6
Type series: W1F_B… (installation deep)
Reference: 400-P-110120-EN-01/03.2023
Dimensions and sectional view
Beispiel für die Masseinheit:
Example for the dimensional units:


LQFK

PP PLOOLPHWHU
Ohne Handnotbetätigung (Standard)
without manual override (standard)
Mit Handnotbetätigung
with manual override
Abmessungen siehe Abbildung links
Dimensions see drawing on the left
3
2
1
6.4
(.252)
M5
40
(
1.57)
ca. 40.9
(ca. 1.61)
10.1
(.398)
57.3
(2.25)
85
(3.35)
ca. 125.9
(ca. 4.96)
Ø45
(Ø1.77)
81.6
(3.21)
59.1
(2.33)
56.5
(2.22)
1P
IWຘOE
0
$  s
Handnotbetätigung
manual override
0$ 
4
Ø20.00×2.00
Ø15.60×1.78
Ø14.00×1.78
Ø23.52×1.78
Installation information
ATTENTION!
Only qualied personnel with mechanical
skills may carry out any maintenance work.
Generally, the only work that should ever be
undertaken is to check, and possibly replace,
the seals. When changing seals, oil or grease
the new seals thoroughly before tting them.
NOTE!
1) When tting the slip-in valves, use
the specied tightening torque for the
mounting screws. The value can be
found in the chapter "Technical data".
5/6
Type series: W1F_B… (installation deep)
Reference: 400-P-110120-EN-01/03.2023
IMPORTANT!
When replacing an old coil with connection
according to DIN 43650/ISO4400 (with other
Pin setup than according to datasheet 400-P-
120120), the new coil can be mounted in 180°
reversed position so that the existing plug
(with 180° earthingPIN) can be connected.
This does not aect the performance data.
Hand lever tted on solenoid (optional)
7)
betätigte Stellung / operated position
Mit Handhebel, rastbar
with hand lever, detentable
+HHB
Mit Handhebel, nicht rastbar
with hand lever, not detentable
+HHNB
Beispiel für die Masseinheit:
Example for the dimensional units:


LQFK

PP PLOOLPHWHU
Ø23
(Ø0.91)
162.9
(6.41)
111.9
(4.41)
50.6
(1.99)
4
(0.16)
Ø45
(Ø1.77)
127
(5)
15
7)
13
2
13
2
As an option, these valves are available with an addi-
tional hand lever. The hand lever can be tted on the
solenoid. Two models can be supplied:“HHB” hand le-
ver with detent feature, and the “HHNB” hand lever
without detent feature.
IMPORTANT!
Hand levers can only be tted to valves that
have a manual override.
6/6
Type series: W1F_B… (installation deep)
Reference: 400-P-110120-EN-01/03.2023
Ordering code
= directional valve, poppet-type, direct acting
= technical design no. hand lever (omit when ordering)
…Q = standard model according to valid data sheet (standard)
= special model after consultation
= current DC
= 3-way/2-position, positive spool
= current AC (connection only possible with DIN EN 175301-803)
= without manual override, with NBR (BUNA) seals (standard)
= without manual override, with FKM (VITON) seals
= with manual override, with NBR (BUNA) seals
= with manual override, with FKM (VITON) seals
= technical design no. directional valve (omit when ordering)
= DIN EN 175301-803 connection, 3-pole 2 P+E with mating plug, IP 65 (standard)
= DIN EN 175301-803 connection, 3-pole 2 P+E
= Deutsch plug connection DT04-2P (with protection diode, IP 67/69K)
= Junior Timer radial plug connection (with protection diode, IP 65)
= flying leads (600 mm)
= without hand lever (standard)
= with hand lever, detentable
= with hand lever, not detentable
= voltage e.g. 24 (24 V)
mating plug
not supplied
Related data sheets
Reference Description
400-P-040011 Form tools
400-P-120120 Solenoid coil D45/207
400-P-040112 Cavity AD
400-P-730121 Threaded port body GADA
400-P-010101 MTTFD Values for Hydraulic Valves
info.ch@bucherhydraulics.com www.bucherhydraulics.com
© 2023 by Bucher Hydraulics AG Frutigen, 3714 Frutigen, Switzerland
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.