1/6
Type series: W1C_B… (installation shallow)
Reference: 400-P-110111-EN-01/03.2023
- Slip-in cartridge valve
- For cavity AA
- All external parts with zinc-nickel plating according to
DIN EN ISO 19598
- Guided valve spool and poppet
- With bidirectional seat-valve shut-o
- With or without manual override
- As an option, hand lever can be tted to solenoid
- De-energized closed
- The slip-on coil can be rotated, and it can be replaced
without opening the hydraulic envelope
- High pressure wet-armature solenoids
- Various plug-connector systems and voltages are
available
Directional valve
2-way/2-position
Q
max
= 40 l/min, p
max
= 315 bar
switching solenoid, direct acting, poppet type
Type series: W1C_B… (installation shallow)
Description
The 2-way/2-position solenoid operated directional
seat valves, series W1C_B (shallow), are size 6, direct
acting, pressure balanced, push-in valves. They are de-
signed on the poppet/seat principle and are leak-tight
in both ow directions (bidirectional seat-valve shut-
o). The guide spool has a seal. This version is the
mounting version "shallow" which ts into the cavity
AA according to factory standard. See separate data
sheet for the mounting version "deep". These valves
are also available with or without manual override,
and with the option of an additional hand lever. All ex-
ternal parts of the screw-in valves are zinc-nickel pla-
ted and are thus suitable for use in the harshest ope-
rating environments. The slip-on coils can be replaced
without opening the hydraulic envelope and can be
positioned at any angle through 360°. These valves
are predominantly used in certain mobile and indus-
trial applications where leak-tight shut-o functions
are crucially important. Examples are where loads,
tensions, or clamping forces must be held without le-
akage. For self-assembly, please refer to the section
related data sheets.
Symbol
1
Without manual override (standard)
2
1
With manual override
2
2/6
Type series: W1C_B… (installation shallow)
Reference: 400-P-110111-EN-01/03.2023
Technical data
General characteristics Description, value, unit
Function group Directional valve
Function 2-way/2-position
Design Slip-in cartridge valve
Controls switching solenoid
Characteristic direct acting, poppet type
MTTFd value 150 years
Construction size NG 6
Mounting attitude unrestricted
Weight 0.85 kg
Cavity acc. factory standard For cavity AA
Tightening torque steel 5.2 Nm
Tightening torque aluminium 5.2 Nm
Tightening torque tolerance ± 5 %
Minimum ambient temperature - 25 °C
Maximum ambient temperature + 50 °C
Surface protection
All external parts with zinc-nickel plating according to DIN EN
ISO 19598
Sealing material see ordering code
Seal kit order number NBR: DS-095-N / FKM: DS-095-V
IMPORTANT!
The less favorable values from the general, hy-
draulic and electrical characteristics determi-
ne the temperature range of the whole valve.
Hydraulic characteristics Description, value, unit
Maximum operating pressure 315 bar
Maximum ow rate 40 l/min
Flow direction see symbol
Hydraulic uid
HL and HLP mineral oil according to DIN 51 524; other uids
on request!
Minimum uid temperature - 25 °C
Maximum uid temperature + 80 °C
Viscosity range 10 … 500 mm²/s (cSt)
Recommended viscosity range 15 … 250 mm²/s (cSt)
Minimum uid cleanliness (cleanlineless class according to ISO
4406:1999)
class 20/18/15
3/6
Type series: W1C_B… (installation shallow)
Reference: 400-P-110111-EN-01/03.2023
Electric characteristics Description, value, unit
Actuator type solenoid coil
Solenoid coils type D45/207
Supply voltage DC 12/24 V DC
Supply voltage AC 115/230 (50 … 60 Hz) V AC
Supply voltage tolerance ± 10 %
Maximum permissible power consumption V DC = 30 ... 32 W / V AC = 31 ... 32 W
Switching time 25 ... 170 ms ( energizing), 15 ... 70 ms (de-energizing)
Relative duty cycle 100 %
Electrical connection coil several connection types available, see ordering code
Protection class solenoid coil to ISO 20 653 / EN 60 529
several classes of protection available, see ordering code (with
appropriate mating connector and proper tting and sealing)
IMPORTANT!
To ensure the performance data is not com-
promised, it is imperative to use coils D45/207
according to data sheet 400-P-120120.
NOTE!
These times are strongly inuenced by
uid pressure, ow rate and viscosity, as
well as by the dwell time under pressure.
Performance graphs
measured with oil viscosity 33.0 mm²/s (cSt), coil at steady-state temperature and 10 % undervoltage
p = f (Q) Performance limit Δp = f (Q) Pressure drop-ow rate characteristic
400-PG-0415
0
50 (700)
100 (1400)
150 (2100)
200 (2900)
250 (3600)
300 (4300)
350 (5000)
Q [l/min (gpm)]
40
3020100
p [bar (psi)]
(10)
(7.5)(5)(2.5)
400-PG-0416
0
5 (70)
10 (140)
15 (215)
20 (285)
25 (350)
Q [l/min (gpm)]
403020100
p [bar (psi)]
(10)(7.5)(5)(2.5)
4/6
Type series: W1C_B… (installation shallow)
Reference: 400-P-110111-EN-01/03.2023
Dimensions and sectional view
Beispiel für die Masseinheit:
Example for the dimensional units:


LQFK

PP PLOOLPHWHU
Ohne Handnotbetätigung (Standard)
without manual override (standard)
Mit Handnotbetätigung
with manual override
Ø45
(Ø1.77)
81.6
(3.21)
59.1
(2.33)
40
(
1.57)
M5
6.5
(.256)
ca. 24.3
(ca. .956)
18
(.708)
57.3
(2.26)
92.9
(3.66)
ca. 117.2
(ca. 4.61)
2
1
0$ 
4
56.5
(2.22)
Handnotbetätigung
manual override
1P
IWຘOE
0$  s
Abmessungen siehe Abbildung links
Dimensions see drawing on the left
Ø20.00×2.00
Ø14.00×1.78
Ø23.52×1.78
Ø15.60×1.78
Installation information
ATTENTION!
Only qualied personnel with mechanical
skills may carry out any maintenance work.
Generally, the only work that should ever be
undertaken is to check, and possibly replace,
the seals. When changing seals, oil or grease
the new seals thoroughly before tting them.
NOTE!
1) When tting the slip-in valves, use
the specied tightening torque for the
mounting screws. The value can be
found in the chapter "Technical data".
5/6
Type series: W1C_B… (installation shallow)
Reference: 400-P-110111-EN-01/03.2023
IMPORTANT!
When replacing an old coil with connection
according to DIN 43650/ISO4400 (with other
Pin setup than according to datasheet 400-P-
120120), the new coil can be mounted in 180°
reversed position so that the existing plug
(with 180° earthingPIN) can be connected.
This does not aect the performance data.
IMPORTANT!
A “de-energized open” function can be crea-
ted by using the 3/2 solenoid cartridge val-
ve and the GADA line-mounting body. In this
case, ports 2 and 3 are used. Port 1 is plugged.
Hand lever tted on solenoid (optional)
7)
betätigte Stellung / operated position
Mit Handhebel, rastbar
with hand lever, detentable
+HHB
Mit Handhebel, nicht rastbar
with hand lever, not detentable
+HHNB
Ø 23
(Ø 0.91)
127
4
(0.16)
50.6
111.9
154.2
°
7)
(1.99)
(4.41)
(6.07)
(5)
2
1
2
1
Beispiel für die Masseinheit:
Example for the dimensional units:


LQFK

PP PLOOLPHWHU
As an option, these valves are available with an addi-
tional hand lever. The hand lever can be tted on the
solenoid. Two models can be supplied:“HHB” hand le-
ver with detent feature, and the “HHNB” hand lever
without detent feature.
NOTE!
These valves can also be tted in the cavity AC
according to factory standard, and in such ca-
ses port 3 then has the same function as port 2.
IMPORTANT!
Hand levers can only be tted to valves that
have a manual override.
6/6
Type series: W1C_B… (installation shallow)
Reference: 400-P-110111-EN-01/03.2023
Ordering code
= directional valve, poppet-type, direct acting
= technical design no. hand lever (omit when ordering)
…Q = standard model according to valid data sheet (standard)
= special model after consultation
= current DC
= 2-way/2-position, de-energized closed
= current AC
= without manual override, with NBR (BUNA) seals (standard)
= without manual override, with FKM (VITON) seals
= with manual override, with NBR (BUNA) seals
= with manual override, with FKM (VITON) seals
= technical design no. directional valve (omit when ordering)
= DIN EN 175301-803 connection, 3-pole 2 P+E with mating plug, IP 65 (standard)
= DIN EN 175301-803 connection, 3-pole 2 P+E
= Deutsch plug connection DT04-2P (with protection diode, IP 67/69K)
= Junior Timer radial plug connection (with protection diode, IP 65)
= flying leads (600 mm)
= without hand lever (standard)
= with hand lever, detentable
= with hand lever, not detentable
= voltage e.g. 24 (24 V)
mating plug
not supplied
Related data sheets
Reference Description
400-P-040011 Form tools
400-P-120120 Solenoid coil D45/207
400-P-040101 Cavity AA
400-P-730111 Threaded port body GABA
400-P-730121 Threaded port body GADA
400-P-010101 MTTFD Values for Hydraulic Valves
info.ch@bucherhydraulics.com www.bucherhydraulics.com
© 2023 by Bucher Hydraulics AG Frutigen, 3714 Frutigen, Switzerland
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.