100-P-000090-EN-20/07.2025
Flow control valce SRR..
4/9
3 Technical data
General characteristics Unit Description, value
Design line mounting
Flow direction P → A controlled
P → R surplus flow discharge
Seals Viton (FPM)
De-energized position orifice closed
Mounting attitude Unrestricted;
preferably with coil at bottom (auto. air bleed)
Electrical characteristics Unit Description, value
Design high pressure; wet armature
Supply voltage 12 or 24 from an electronic controller
Power consumption W 21 at 12 V coil and Imax. = 2,3 A
21 at 24 V coil et Imax. = 1,15 A
Dither frequency required Hz 100 (pay attention to Imax.)
Relative duty cycle 100% at Imax.
Protection class (with a properly-fitted plug) AMP Junior Timer IP65
Deutsch plug IP67
DIN EN 60529
Electrical connection AMP Junior Timer plug connector (2-pole)
Deutsch plug DT04-2P-EP04
Hydraulical characteristics Unit Description, value
Constant flow range l/min 10, 16, 25, 32, 40, 50, 63, 80
1)
Inlet flow l/min max. 100
1)
Operating pressure bar max. 315
2)
Leakage cm
3
/min max. 100 at 100 bar
1)
Minimum pressure difference (pressure com
pensator)
bar 7
Control accuracy (depending on the nominal flow):
Load-dependency when under pressure
Hysteresis when operated
max. ± 2.5%
3)
max. ± 3.5%
3)
Fluids mineral oil to DIN 51524
4)
Fluid temperature range °C -20 ... +80
Viscosity range mm
2
/s 10 ... 300
Max. admissible level of contamination of the
hydraulic fluid
ISO 4406 class 20/18/15
1) Values refer to an oil viscosity of 35 mm
2
/s (cSt).
2) For higher pressures consult Bucher Hydraulics
3) Values refer to the selected flow range.
4) for other fxluids, consult Bucher Hydraulics.