Stack-Mounting Counterbalance Valve, NG 6
Q
max
= 80l/min,p
max
= 350bar
pilot operated, poppet type
Series SNSA…
1/5
Reference: 300-P-360101-EN-01
Issue: 06.2023
S Controlled movement of negative loads
S Controls the oil leaving the actuator (counterbalance
function)
S Load holding via leak-free poppet valve
S Secondary relief protection for the actuator
S For plate mounting valve, Interface NG 6 to
ISO 4401-03-02
1 Description
Counterbalance valves prevent actuator “runaway” in the
event of negative loads. The flow leaving the actuator (the
A line in the example) is piloted and controlled by the flow
entering the actuator (the B line), ensuring a cavitation-free
lowering of the load, as long as the valve pressure setting
is not exceeded (see application example). A counterbal
ance valve must be capable of holding the load without leak
age. The design of this valve is based on a pilot assisted
pressure relief valve (see pressure settings). The pressure
in the actuator inlet line causes the relief valve in the actua
tor outlet line to open. The level of pilot pressure which is re
quired is determined by the valve's pilot area ratio and by the
pressure generated by the load itselfs (see pressure set
tings).
To ensure a reliable secondary relief function (e.g. for ther
mal expansion) the related directional valve must have a
centre condition in which ports A and B are connected to
Tank T (spool type function G).
2 Symbol
3 Technical data
General characteristics Description, value, unit
Designation stack-mounting counterbalance valve
Design pilot operated, poppet type
Mounting method stack-mounting
Size NG 6, interface ISO 4401-03-02
Weight SNSA-A .. / -B ..-6 = 1.25 kg
SNSA-AB ..-6 = 1.50 kg
Mounting attitude unrestricted
Flow direction see symbols
Maximum operating pressure 350 bar