Stack-Mounting Counterbalance Valve, NG 6
Q
max
= 80l/min,p
max
= 350bar
pilot operated, poppet type
Series SNSA…
1/5
Reference: 300-P-360101-EN-01
Issue: 06.2023
S Controlled movement of negative loads
S Controls the oil leaving the actuator (counterbalance
function)
S Load holding via leak-free poppet valve
S Secondary relief protection for the actuator
S For plate mounting valve, Interface NG 6 to
ISO 4401-03-02
1 Description
Counterbalance valves prevent actuator “runaway” in the
event of negative loads. The flow leaving the actuator (the
A line in the example) is piloted and controlled by the flow
entering the actuator (the B line), ensuring a cavitation-free
lowering of the load, as long as the valve pressure setting
is not exceeded (see application example). A counterbal
ance valve must be capable of holding the load without leak
age. The design of this valve is based on a pilot assisted
pressure relief valve (see pressure settings). The pressure
in the actuator inlet line causes the relief valve in the actua
tor outlet line to open. The level of pilot pressure which is re
quired is determined by the valve's pilot area ratio and by the
pressure generated by the load itselfs (see pressure set
tings).
To ensure a reliable secondary relief function (e.g. for ther
mal expansion) the related directional valve must have a
centre condition in which ports A and B are connected to
Tank T (spool type function G).
2 Symbol
3 Technical data
General characteristics Description, value, unit
Designation stack-mounting counterbalance valve
Design pilot operated, poppet type
Mounting method stack-mounting
Size NG 6, interface ISO 4401-03-02
Weight SNSA-A .. / -B ..-6 = 1.25 kg
SNSA-AB ..-6 = 1.50 kg
Mounting attitude unrestricted
Flow direction see symbols
Maximum operating pressure 350 bar
300-P-360101-EN-01/06.2023
Series SNSA
2/5
Description, value, unitGeneral characteristics
Adjustment change pressure range N1
pressure range N2
pressure range M1
pressure range M2
140…350 bar (pilot ratio 4.5:1)
70…280 bar (pilot ratio 3:1)
70…175 bar (pilot ratio 4.5:1)
30…105 bar (pilot ratio 3:1)
Opening pressure via check valve standard
on request
ca. 1.7 bar
ca. 0.3 bar
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please contact BUCHER
Hydraulic fluid temperature range -25°C … +80°C
Viscosity range 10 … 300 mm
2
/s (cSt)
Maximum flow rate 80l/min
Surface corrosion protection all exposed parts with zinc-nickel plating
Minimum fluid cleanliness
Cleanliness class to ISO 4406:1999
class 20/18/15
4 Application example and pressure settings
5 Performance graphs
300-P-360101-EN-01/06.2023
Series SNSA
3/5
6 Dimensions & sectional view
7 Schematic section
showing the relevant ports
Seal kit Nr. DS-241
It. Qty. Qty. Qty. Description Size
1 4 2 2 O-ring Nr. 017 17.17 x 1.78 N90
2 2 1 1 O-ring Nr. 015 14.00 x 1.78 N90
3 4 4 4 O-ring Nr. 012 9.25 x 1.78 N90
4 2 1 1 Backup ring 017
5 2 1 1 Backup ring 016
6 2 1 1 Backup ring 015
SNSA-A-6
SNSA-B-6
SNSA-AB-6...
300-P-360101-EN-01/06.2023
Series SNSA
4/5
8 Installation information
ATTENTION!
Maintenance work may only be carried out care
fully by qualified personnel. When mounting the
valve, make sure that the connection hole pattern
matches that of the mating surface. (Do not mix up
the connection side and the valve side). When re
placing seals, make sure that the seals are well
oiled or greased. The function cartridge must be
mounted with the specified tightening torque.
9 Ordering code
S = stack valve
N = counterbalance valve
S = poppet type
A … Q = standard model per current data sheet
Z … R = special features by arrangement on request
A = function A
B = function B
AB = function in A and B
6 = Nominal size 6
S = screw adjustment
N1 = pressure range 140 … 350 bar (normal version, standard design)
pilot ratio 4.5:1
N2 = pressure range 70 … 280 bar (on request)
pilot ratio 3:1
M1 = pressure range 70 … 175 bar (medium version, standard design)
pilot ratio 4.5:1
M2 = pressure range 30 … 105 bar (on request)
pilot ratio 3:1
= valves are shipped with pressure set at the maximum for the
specified pressure range e.g. if N1, then 350 bar
18 = check valve opening pressure 1.7 bar (standard)
03 check valve opening pressure 0.3 bar (on request)
(blank) = NBR (nitril-butadien-rubber / BUNA) seals (standard)
V = FKM (fluorocarbon rubber / VITON) seals
(special seals - please consult BUCHER)
Ex.
6 _
18
N1
SAB
ASN
S
IMPORTANT!
Two check valve cracking pressures are avail
able. Use the 25 psi (1.7 bar) check unless actua
tor cavitation is a concern.
300-P-360101-EN-01/06.2023
Series SNSA
5/5
10 Related data sheets
Reference Description
400-P-030101 Interface NG 6 to ISO 4401-03-02
E 2023 by Bucher Hydraulics AG Frutigen, CH-3714 Frutigen
www.bucherhydraulics.cominfo.ch@bucherhydraulics.com
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Classification: 430.305.300.305.305