6.1.2E
P 1/2
Aenderungen vorbehalten
subject to change
droits de modification réservé
con riserva di cambiamenti tecnici
16.03.2001
RSE and RSG Pipe rupture valves
6.1 General:
• Type: plate valve
• Mounting method: screw-type cartridge
• Ports: P, Z see point 10
• Mounting position: any
• Weight: see point 10
6.2 Hydraulic characteristics:
• Size: 1/4, 3/8, 1/2, 18x1,5
• Min. settable closing flow: 3 l/min (G1/4")
• Max. settable closing flow: 75 l/min (G1/2")
• Max. working pressure: 400 bar
• Hydraulic medium: mineral oil per DIN 51524 and
DIN 51525 (HL/HLP),
inquire about other media
• Hydraulic medium
temperature range: -20°C...+80°C,
inquire about other temperatures
• Viscosity range: 2.8 mm
2
/s up to 380 mm
2
/s
• Filtering: NAS 1638 class 9, β10 ≥ 75.
• for protecting hydraulic consumers
• for direct installation in cylinders
4.1 If, when the oil is flowing from Z to P, the pressure difference in
the valve exceeds a value that corresponds to the preloading
pressure (approx. 1 bar), the plate is forced against the valve
seat and seals the opening passage leakfree.
4.2 The pipe rupture valve is opened again automatically when the
pressure at port P is higher than that at port Z.
• prevents uncontrolled movement of the cylinder if a pipe or
hose burst occurs.
• settable closing flow
1. General description
3. Application
4. Functional description, sectional view
6. Characteristics
• simple adjustment of flow rates
• minimal spatial requirement thanks to compact design.
2. Advantages of Beringer's pipe rupture valve
• This valve must only be used for the purpose for which it has
been designed.
• It must only be adjusted by trained staff.
• The hydraulic system must be depressurized and checked
before the valve is dissasembled.
• The valve must not be opened without the express permission
of the manufacturer.
7. Safety instructions
• Observe all port designations.
• Observe the tightening torques (see dimension diagram).
• Bleed the hydraulic system before putting it into operation.
8. Assembly instructions
5. Symbol
P
Z
(Please contact Beringer if machinery is required for use beyond these
tolerances)
Z
P
sealing plate
lock-nut
1. Screw in the sealing plate until it sits on the seat.
2. Set the flow acc. to the setting diagrams (see section 11).
3. Tighten the lock-nut to the specified torque (see section 10).
9. Adjustment instructions