6.1.2E
P 1/2
Aenderungen vorbehalten
subject to change
droits de modification réservé
con riserva di cambiamenti tecnici
16.03.2001
RSE and RSG Pipe rupture valves
6.1 General:
Type: plate valve
Mounting method: screw-type cartridge
Ports: P, Z see point 10
Mounting position: any
Weight: see point 10
6.2 Hydraulic characteristics:
Size: 1/4, 3/8, 1/2, 18x1,5
Min. settable closing flow: 3 l/min (G1/4")
Max. settable closing flow: 75 l/min (G1/2")
Max. working pressure: 400 bar
Hydraulic medium: mineral oil per DIN 51524 and
DIN 51525 (HL/HLP),
inquire about other media
Hydraulic medium
temperature range: -20°C...+80°C,
inquire about other temperatures
Viscosity range: 2.8 mm
2
/s up to 380 mm
2
/s
Filtering: NAS 1638 class 9, β10 75.
for protecting hydraulic consumers
for direct installation in cylinders
4.1 If, when the oil is flowing from Z to P, the pressure difference in
the valve exceeds a value that corresponds to the preloading
pressure (approx. 1 bar), the plate is forced against the valve
seat and seals the opening passage leakfree.
4.2 The pipe rupture valve is opened again automatically when the
pressure at port P is higher than that at port Z.
prevents uncontrolled movement of the cylinder if a pipe or
hose burst occurs.
settable closing flow
1. General description
3. Application
4. Functional description, sectional view
6. Characteristics
simple adjustment of flow rates
minimal spatial requirement thanks to compact design.
2. Advantages of Beringer's pipe rupture valve
This valve must only be used for the purpose for which it has
been designed.
It must only be adjusted by trained staff.
The hydraulic system must be depressurized and checked
before the valve is dissasembled.
The valve must not be opened without the express permission
of the manufacturer.
7. Safety instructions
Observe all port designations.
Observe the tightening torques (see dimension diagram).
Bleed the hydraulic system before putting it into operation.
8. Assembly instructions
5. Symbol
P
Z
(Please contact Beringer if machinery is required for use beyond these
tolerances)
Z
P
sealing plate
lock-nut
1. Screw in the sealing plate until it sits on the seat.
2. Set the flow acc. to the setting diagrams (see section 11).
3. Tighten the lock-nut to the specified torque (see section 10).
9. Adjustment instructions
6.1.2E
P 2/2
Aenderungen vorbehalten
subject to change
droits de modification réservé
con riserva di cambiamenti tecnici
16.03.2001
10. Dimension diagram
10.1 RSE
10.3 Location hole
11. Setting diagram
10.2 RSG
12. Type code
RS RS
Settable closing flow
/
RS
Pipe
rupture valve
E E
G G
Type
Size
1/4 1/4
3/8 3/8
1/2 1/2
M18x1.5 M18x1.5
/
01020304050607080
0
1
2
3
4
5
RSE 1/4
RSE 3/8
RSE M18x1.5
RSE 1/2
Setting clearance s [mm]
Closing flow Q [l/min]
L
G
G
A/F / MA
P
Z
G
b
c
S
a
A/F2 / MA2
A/F3 / MA3
A/F1
MA1
e
d
P
Z
f
g
G
P
Z
measured at 70 mm
2
/s
Size A/F A/F1 A/F2 A/F3 MA MA1 MA2 MA3
(Nm) (Nm) (Nm) (Nm)
1/4 19 2.5 8 5.5 20 2.1 1.5 1.5
3/8 22 2.5 10 5.5 35 2.1 1.5 1.5
1/2 27 3 12 7 60 4.9 3.5 3.5
M18x1.5 22 2.5 10 5.5 40 2.1 1.5 1.5
up to 75 l/min ....
(must be min. 40% above max. working flow)
Size G a b c d e f g L Weight (kg)
RSE RSG
1/4 G1/4 21 9 9 8.2 2.5 30 36 58 0.006 0.080
3/8 G3/8 23 11 9 10 3.5 32 40 58 0.013 0.115
1/2 G1/2 29 13 12 13.5 4 35 45 65 0.022 0.195
18x1.5 M18x1.5 23 11 9 10 3.5 32 40 58 0.013 0.115