3/4
Type series: ERVH-G-5-…
Reference: 170-P-052005-EN-01/01.2021
Dimensions and sectional view
G1“
70
Ø 30.50
+0,1
20°
A
X
26.60x29.50
26.70x01.78
SW14
B
A
Ø29
16 19
G1"
0.02
A
Ø 29.5H8
max.Ø26
Rz 6.3
min. 23 .40
min. 50
Ø14
Ø4
70
32 .5
Ø14
Ø 29.5
7
M = 160 Nm
14
Installation information
NOTE!
When tting the screw-in cartridge valve, use
the specied tightening torque. The value
can be found in the chapter technical data.
Orices or nozzles are to be placed after the check
valve. If this is not possible, a right-angled bore
must be designated between the check valve
and the nozzle. (see data sheet 170-P-059000).
ATTENTION!
When tting the valve, make sure that it is
rmly seated on the sealing surface and that it
is not deformed by the use of excessive force.
Application Notes
NOTE!
The maximum operating pressure must not be
exceeded even when pressure peaks occur. In
applications such as accumulator circuits, whe-
re sudden pressure can be applied to the valve
in the free- ow direction, ensure that the speci-
ed ow ratings are not exceeded. Buyers bear
the sole responsibility for ensuring that the val-
ve is suitable for their applications and must be
substantiated by trials or testing, if necessary.
ATTENTION!
The valves are only suitable for pressure relief
in the opening direction to a limited extent. (if
necessary, please consult Bucher Hydraulics).
ERVH-G-5 = check valve / screw-in cartridge valve
ERG-01 = dimension of the cavity for screw-in cartridge valve ERVH-G-5
The dimensions specied apply to the mounted state.