1/4
Type series: ERVH-G-5-
Reference: 170-P-052005-EN-01/01.2021
- Screw-in cartridge valve
- Hydraulic pilot-operated
- Virtually leak-proof in closed condition
- High pressure rating
Check valve
Spring loaded check
Q
max
= 125 l/min, p
max
= 350 bar
plate type
Type series: ERVH-G-
5-
Description
The ERVH series plate-type check valve is characteri-
zed by the fact that it can be opened by a hydraulic
pilot pressure at X against the no-ow direction and
by very high pressure load capacity. The plate-type
spring-loaded check valve is very robust, extremely
leak proof and dirt resistant. Valve seat, poppet and
body are hardened. The properties of the sealing fa-
ces have been enhanced by precision mechanical pro-
cessing. The valves prevent ow in the screw-in direc-
tion (B to A) and open in the opposite direction. The
valve is available in nominal sizes 1, 2, 3, 4 and 5.
Symbol
B
A
X
2/4
Type series: ERVH-G-5-…
Reference: 170-P-052005-EN-01/01.2021
Technical Data
General Characteristics Description, value, unit
Function group Check valve
Function Spring loaded check
Design Screw-in cartridge valve
Characteristic plate type
Construction size nominal size 5
Thread size G 1”
Mounting attitude unrestricted
Weight 0,26 kg
Tightening torque steel 160 Nm
Hydraulic Characteristics Description, value, unit
Maximum operating pressure 350 bar
Maximum ow rate 125 l/min
Nominal ow rate 80 l/min
Flow direction see symbol
Hydraulic uid
HL and HLP mineral oil according to DIN 51 524; other uids
on request!
Minimum uid temperature - 30 °C
Maximum uid temperature + 80 °C
Viscosity range 10 … 500 mm²/s (cSt)
Minimum uid cleanliness (cleanlineless class according to ISO
4406:1999)
class 20/18/15
Geometric Dierential Area Ratio 1:3
Opening pressure 1.0 bar
NOTE!
For other values plea-
se contact Bucher Hydraulics.
Performance graphs
measured with oil viscosity 33.0 mm²/s (cSt)
Δp = f (Q) Pressure drop-ow rate characteristic
Q[l/min]
p[bar]
5
4
3
2
1
0
0
25
50 75 100
125
Q
Nenn
Calculation of pilot pressure
Pilot pressure =
load pressure A - back pressure B
opening area ratio i
+
3 + back pressure B
3/4
Type series: ERVH-G-5-…
Reference: 170-P-052005-EN-01/01.2021
Dimensions and sectional view
G1
70
Ø 30.50
+0,1
20°
ERG-01
A
X
26.60x29.50
26.70x01.78
SW14
B
A
Ø29
16 19
G1"
0.02
A
Ø 29.5H8
max26
Rz 6.3
min. 23 .40
min. 50
Ø14
Ø4
70
32 .5
Ø14
Ø 29.5
7
M = 160 Nm
14
ERVH-G-5
Installation information
NOTE!
When tting the screw-in cartridge valve, use
the specied tightening torque. The value
can be found in the chapter technical data.
Orices or nozzles are to be placed after the check
valve. If this is not possible, a right-angled bore
must be designated between the check valve
and the nozzle. (see data sheet 170-P-059000).
ATTENTION!
When tting the valve, make sure that it is
rmly seated on the sealing surface and that it
is not deformed by the use of excessive force.
Application Notes
NOTE!
The maximum operating pressure must not be
exceeded even when pressure peaks occur. In
applications such as accumulator circuits, whe-
re sudden pressure can be applied to the valve
in the free- ow direction, ensure that the speci-
ed ow ratings are not exceeded. Buyers bear
the sole responsibility for ensuring that the val-
ve is suitable for their applications and must be
substantiated by trials or testing, if necessary.
ATTENTION!
The valves are only suitable for pressure relief
in the opening direction to a limited extent. (if
necessary, please consult Bucher Hydraulics).
ERVH-G-5 = check valve / screw-in cartridge valve
ERG-01 = dimension of the cavity for screw-in cartridge valve ERVH-G-5
The dimensions specied apply to the mounted state.
4/4
Type series: ERVH-G-5-…
Reference: 170-P-052005-EN-01/01.2021
Ordering code
ERVH
= hydraulic pilot-operated check valve, screw-in type
G
= whitworth pipe thread G1“
5
= nominal size 5, Q
Nominal
80 l/min
blank
= NBR (Nitrile) seal (standard) (Item no.: 170629755)
V
= FKM (Viton) seal (Item no.: 170529755)
GERVH
-
5
--
Related data sheets
Reference Description
170-P-059000 Using nozzles or orices before a Check Valve
info.de@bucherhydraulics.com www.bucherhydraulics.com
© 2021 by Bucher Hydraulics Dachau GmbH, 85221 Dachau, Germany
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.