4/2 and4/3 Solenoid Directional Valve, ISO Size 03
Q
max
= 18l/min,p
max
= 160bar
Direct acting, with EX-safty solenoid coil
Series EEX-WED…
1/5
Reference: 400-P-190310-EN-03
Issue: 09.2020
Valve:
S Slip-on coil design, coils can be changed
without opening hydraulic envelope
S With manual override
S Interface to ISO 4401-03-02
Solenoid coil:
S To IEC/EN 60079-0, IEC/EN 60079-7, EN 60079-18
To EN 60079-31
S For equipment in Category 2
gas:
II 2 G Ex eb mb IIC T4 Gb
dust:
II 2 D Ex tb IIIC T120°C Db
1 Description
Series EEX-WED...-6 spool valves are direct acting units.
The main valve components are a steel body, a spring-
centered spool and wet armature solenoids with pressure-
tight core tube and a slip-on coil which is certified for use
in explosion-hazard areas. The coil slips over the core tube
and is retained by a knurled nut. The solenoid housing is
made of steel with spray painted finish. The solenoid arma
ture is of the oil-immersed type. The terminal box on the coil
is provided with a cable gland for cable diameter of 6 … 12
mm. Valves are supplied complete with cable entry gland
but without cable. The spool is offset by the solenoid force
and brought back to its deenergised position by return or
centering springs. For the detented model EEX-
WED-42-C-6, the maximum flow rate is limited to 10 l/min.
Ex: solenoid conforms to the European standards
IEC/EN 60079-0, IEC/EN 60079-7, EN 60079-18
EN 60079-31
Gas:
e: increased security
m: encapsulation
Group II: for use in the potentially explosive area
T4: temperature class for gas
Dust:
t: protection by enclosure
Group IIIC: use in areas with combustible dust
T120 °C: temperature class for dust
Verification certificates:
Europe: BVS 16 ATEX E 036 X
others on request
2 Technical data
General characteristics Description, value, unit
Designation 4/2 and 4/3 solenoid directional valve
Design manifold-mounting, two-stage
Mounting method 4 x ∅ 5,5 holes for M5x45 cap screws
Tightening torque 5.2 Nm ± 10 %
Size size 03 interface to ISO 4401-03-02 / DIN 24 340 A6
Weight 2.2 kg (1 solenoid)
3.0 kg (2 solenoid)
Mounting attitude horizontal recommended
(vertical mounting makes air bleeding difficult)
Ambient temperature range see hydraulic and electrical characteristics