4/2 and 4/3 Solenoid Directional Valve, ISO Size 05
Q
max
= 90l/min,p
max
= 315bar
Two-stage design, with EX-safty solenoid coil
Series EEXD-WEV…
1/6
Reference: 400-P-191210-EN-03
Issue: 06.2021
Valve:
S Slip-on coil design, coils can be changed
without opening hydraulic envelope
S With manual override
S Interface to ISO 4401-05-04
Solenoid coil:
S To EN 60079-0, EN 60079-1, EN 60079-31
S For equipment in Category 2
gas:
II 2 G Ex d IIC T6, T4 Gb
dust:
II 2 D Ex tb IIIC T85 °C, T130° C Db
1 Description
Series EEXD-WEV...-10 high performance spool valves
are two-stage units which use the follower spool principle.
The main valve components are a steel body, a spring-
centered follower spool assembly and wet armature sole
noids with pressure-tight core tube and a slip-on coil which
is certified for use in explosion-hazard areas. The coil slips
over the core tube and is retained by a knurled nut. The
solenoid housing is made of cast iron with spray painted fin
ish. The solenoid housing is threaded M20 x 1,5 for a cable
entry gland. The cable entry gland (which also must be
certified to IEC/EN 60079-1) is not supplied with the valve
and, if required, must be ordered as a separate item:
Cable entry gland type AGRO 1820. 16.26 M20 x 1,5 (for
cable ø11...13). The valves provide reliable service even
under the severest operating conditions such as high flow
rates, high operating pressures, long periods without
switching and large temperature fluctuations. The highly ef
fective spool actuation method combines the advantages
of both direct acting and two-stage solenoid valves, with
out incurring the well known disadvantages of either type.
The main spool is offset by both the solenoid force and the
P - T *) pressure difference inside the valve. The greater the
P - T pressure difference, the grea-ter the offsetting force.
It is brought back to its deenergised position in the same
way, using the P - T pressure difference and without the
need for heavy centering springs. *) The pressure in P must
exceed that in T and the valve must be connected in the
conventional manner i.e. press-sure to P, T to tank.
Ex: Solenoid conforms to the European standards
IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 60079-18
Gas:
d: Flameproof enclosures
Group IIC: For use in the potentially explosive area
T6, T4: Temperature class for gas
Gb: For use in Zone 1 (Zone 2) with foreseeable faults
Dust:
tb: protection by enclosure
Group IIIC: For use in flammable dust atmospheres
T85 °C, T130 °C: Temperature class for dust
Db: For use in Zone 21 (Zone 22) with foreseeable faults
Verification certificates:
Europe BVS 15 ATEX E135 (ATEX)
others on request
2 Technical data
General characteristics Description, value, unit
Designation 4/2 and 4/3 solenoid directional valve
Design manifold-mounting, two-stage
Mounting method 4 x ∅ 6,4 holes for M6x60 cap screws
Tightening torque 9 Nm ± 10 %
Size size 05 interface to ISO 4401-05-04 / DIN 24 340 A10