2/2…4/3 Solenoid Directional Seat Valve, ISO Size 03
Q
max
= 20l/min (5.3 gpm),p
max
= 315bar (4500 psi)
Bidirectional leak-proof shutoff, direct acting, with EX-safety solenoid coil
Series EEX-W2N…
1/7
Reference: 400-P-115210-EN-02
Issue: 02.2018
Valve:
S With cartridge valve, type EEX-W1.B…
S Interface to ISO 4401-03-02
S Bidirectional leak-proof shutoff or flow
S De-energised closed
S Guided valve spool and poppet
S Available in two mounting versions
S With or without manual override
Solenoid coil:
S To IEC/EN 60079-0, IEC/EN 60079-7,
IEC/EN 60079-18
S For equipment in Category 2 (Zones 1 and 2)
S Certificate of conformity:
BASEEFA 02 ATEX 0199 X
II 2 G Ex e mb IIC T4 Gb
1 Description
The EEX-W2N… series of 2/2 … 4/3 solenoid operated di
rectional seat valves are direct acting, pressure balanced,
manifold-mounting valves with a size 03 interface to ISO
4401-03-02. An EX-protected solenoid for explosive gas at
mospheres (II 2 G) is used to provide electrical operation of
the cartridge. The main components of the valves are a ma
nifold-mounting body and the push-in 2/2 or 3/2 directional
seat valve cartridge (type EEX-W1.B…). Dependent on the
operating position, the ports are either closed with virtually
zero leakage, or open and flow is possible in either direction.
These solenoid operated seat valves are also available with
or without manual override lever. For applications where a
check valve or an orifice in the P port is necessary, either of
these features can be included as an option. They are suita
ble where leak-tight shut-off functions are crucially import
ant. Examples are where loads, tensions, or clamping
forces must be held without leakage. All external parts of the
valve are corrosion-protected, and the valves are thus also
suitable for use outdoors.
Ex: Solenoid conforms to the European standards
IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 60079-18
e: Increased safety
mb: Encapsulation
Group IIC: For use in explosive gas atmospheres
T4: Max. surface temperature 135 °C
Gb: For use in Zone 1 (Zone 2) with foreseeable faults
Certificate of conformitys:
BASEEFA 02 ATEX 0199 X
IECEx BAS13.0093 X (on request)
2 Technical data
General characteristics Description, value, unit
Designation 2/2, 3/2, 3/3 or 4/3 solenoid operated
directional seat valve
Design manifold-mounting, bidirectional leak-proof shutoff,
direct acting poppet and valve-spool design
(pressure balanced) with EX-protected solenoid
Mounting method 4 x 5.5 holes for M5x30 cap screws
Tightening torque 5.2 Nm 10 % (4 ft-lbs 10 %)
Size size 03 interface to ISO 4401-03-02 / DIN 24 340 A6
400-P-115210-EN-02/02.2018
Series EEX-W2N…
2/7
Description, value, unitGeneral characteristics
Weight 2.3 kg (1 solenoid)
3.6 kg (2 solenoid)
Mounting attitude unrestricted
Ambient temperature range see hydraulic and electrical characteristics
Hydraulic characteristics Description, value, unit
Maximum operating pressure 315bar (4500 psi)
Maximum flow rate 20 l/min (5.3 gpm)
Flow direction see symbols
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please contact BUCHER
Ambient temperature range
1)
-25°C … +80°C (-13 °F … +176 °F)
Hydraulic fluid temperature range
1)
-25°C … +80°C
2)
(-13 °F … +176 °F)
2)
Viscosity range 10…500mm
2
/s (cSt), recommended 15...250mm
2
/s (cSt)
Minimum fluid cleanliness
Cleanliness class to ISO 4406:1999
class 20/18/15
Electrical characteristics Description, value, unit
Supply voltage 24V DC
230V AC
In AC solenoids, rectifier is integrated.
Supply voltage tolerance ±10%
Ambient temperature range
1)
-40°C … +40°C (-40 °F … 104 °F)
(operation as T4)
Temperatue class T1 … T4
EX-protection marking II 2 G, Ex e mb IIC T4 Gb
Nominal power consumption 31,9 W at 20 °C (31.9 W at 68 °F)
Relative duty cycle 100%
Protection class to ISO20653 / EN60529 IP54
(with properly fitted cable gland and properly made cable connection)
Electrical connection Shipped without cable gland (M20 x 1.5) and without cable
Cable-entry temperature may exceed 70 °C
IMPORTANT!:
1)
The less favourable values from the hydraulic
and electrical characteristics determine the tem
perature range of the whole valve.
IMPORTANT!:
2)
The maximum fluid temperature must not ex
ceed the permissible ambient temperature for the
whole valve.
400-P-115210-EN-02/02.2018
Series EEX-W2N…
3/7
3 Performance graphs
IMPORTANT!
Detailed performance data and other hydraulic
characteristics can be found in the data sheet for
the respective 2/2 or 3/2 solenoid operated car
tridge seat valve (series EEX-W1.B…) that is fit
ted. See “Related data sheets”.
ATTENTION!
The performance figures in the data sheet for the
cartridge valve refer just to the cartridge itself.
Take into account the additional pressure drop in
the body into which it is fitted.
p = f (Q) Pressure drop - Flow rate characteristic
through orifice (metering function)
P0467.ai
0
50 (700)
100 (1400)
150 (2100)
200 (2900)
250 (3600)
315 (4500)
Q [l/min (gpm)]
20151050
p [bar (psi)]
(5.3)(4)(2.6)(1.3)
Ø 1.2
Ø 1.0
Ø 1.4
1.2 and 1.4 orifices drilled out by customer!
p = f (Q) Pressure drop - Flow rate characteristic
through push-in check valve
P0466.ai
0
2 (30)
4 (60)
6 (90)
8 (115)
10 (140)
Q [l/min (gpm)]
20151050
p [bar (psi)]
(5.3)(4)(2.6)(1.3)
400-P-115210-EN-02/02.2018
Series EEX-W2N…
4/7
22 S22 O
A
TP
a
a
A
P
a
A
T
A
TP
PA T
A
TP
a
A
TP
32 S32 O33 R43 F43 G43 A
a
A
P
a
A
P
A
TP
A
TP
PA T
A
TP
a
A
TP
a
PA T
PA T
PA T
A
TP
ba
PA TB
PA TB
PA TB
ba
AB
TP
ba
AB
TP
AB
TP
a b
Code Symbols Remarks Operating principle
2-way circuit
(with 2/2 cartridge seat valve)
3-way circuit
(with 3/2 cartridge seat valve)
3-way circuit
(with 2/2 cartridges)
4-way circuit
(with 3/2 cartridge seat valves)
For 2/2 circuits, the customer
must plug the T port!
For 2/2 circuits, the customer
must plug the P port!
For 2/2 circuits, the customer
must plug the T port!
For 2/2 circuits, the customer
must plug the T port!
Unacceptable heating-up
Energising solenoids a and b
simultaneously is not permitted!
Unacceptable heating-up
Energising solenoids a and b
simultaneously is not permitted!
Unacceptable heating-up
Energising solenoids a and b
simultaneously is not permitted!
Unacceptable heating-up
Energising solenoids a and b
simultaneously is not permitted!
400-P-115210-EN-02/02.2018
Series EEX-W2N…
5/7
4 Dimensions & sectional view
2/2 and 3/2 solenoid operated directional seat valve (single-solenoid model)
93.3
(3.67)
2.4
(0.09)
163.3
(6.43)
(0.89)
(1.86)
18.4
(0.72)
70
(2.76)
(1.81)
13.7
(0.54)
45
171.4
(6.75)
T
A
B
P
4 4
24
3)
M
A
= 5,2 [Nm] 5 % M
A
= 5,2 [Nm] 5 %
M
A
= 15 [Nm] 10 %
0,01 / 100
Rz max 4
6)
M5
4)
(4 ftlbs 5 %) (4 ftlbs 5 %)
(11 ftbls 10 %)
(0.3)
(1.77)
3/3 and 4/3 solenoid operated directional seat valve (double-solenoid model)
400-P-115210-EN-02/02.2018
Series EEX-W2N…
6/7
Seal kit no. DS-475-N
5)
Item Qty. Description
1 4 O-ring no. 012 9,25x1,78 N90
2 2 NBR seal kit no. DS-263-N for seat valve,
type EEX-W1...
IMPORTANT!
3)
Can be chosen with or without manual
override. (see ordering code)
4)
Valve mounting bolts M5x30
(included in the delivery)
5)
Seal kit with Viton seals, no. DS-475-V
6)
Required surface finish on the
mounting face (valve pad)
4.1 Push-in check valve
To prevent uncontrolled back-pressure effects or back-flow
of oil, series EEX-W2N… solenoid operated directional seat
valves can be supplied with an optional push-in check
valve, type RCA-5, and a special body. The check valve al
lows free flow from P to A or B, but prevents flow in the oppo
site direction, with no leakage.
P
Application: when several valves are supplied in parallel, for
instance, and the supply pressure in P drops below the
pressure in A or B (another circuit is vented, or a lightly-
loaded actuator is operated). The pressure in service line A
or B is then higher, but the check valve prevents it from fal
ling during such operations in other circuits.
4.2 Orifice (metering function)
An orifice disc (type D10, 1.0 mm) must be used when, as
a consequence of the operating conditions that exist, circuit
operations may result in flow rates that exceed the perform
ance limit of the valve.
IMPORTANT!
The orifice disc fitted for this purpose is 1.0 mm.
Customers may drill it out to 1.4 mm maximum
(see performance graphs).
P
Application: when used for charging accumulators, for in
stance, or when the solenoid operated directional seat
valves are used to pilot other valves.
5 Installation information
COMMISSIONING
S For short-circuit protection, each solenoid must be pre
ceded by a fuse conforming to B588 or IEC269 with a
maximum rating of 2 A (AC) or 6 A (DC).
S The solenoid coils must only be operated when they are
fitted on the associated valve. For more information on in
stallation and commissioning, please refer to the operat
ing instructions supplied with the solenoid coil.
ATTENTION!
Ratings given in the operating instructions
Pay attention to the relevant operating instruc
tions! If in doubt, the ratings in the operating in
structions apply.
ATTENTION!
Only qualified personnel with mechanical skills
may carry out any maintenance work. Generally,
the only work that should ever be undertaken is to
check, and possibly replace, the seals. When
changing seals, oil or grease the new seals tho
roughly before fitting them.
ATTENTION!
Authorised persons
The tasks described here may only be carried out
by authorised personnel. Authorised personnel
are those who have electro-technical training (EN
60204-1).
IMPORTANT!
When fitting the cartridges, use the specified tight
ening torque for the mounting bolts. The marking
"Valve End" on the adapter sleeve must be
mounted towards the valve flange! No adjust
ments are necessary, since the cartridges are set
in the factory.
IMPORTANT!
Minimum dimensions of the mating body
101 x 46 x 43 mm
See also the user manual.
400-P-115210-EN-02/02.2018
Series EEX-W2N…
7/7
6 Ordering code
EEX = EX-protected coil instead of standard solenoid coil
(for details, see electrical characteristics)
W2 = solenoid directional seat valve, manifold mtg.
N = open crossover
22 S = 2/2 function, P closed
22 O = 2/2 function, P A connected
32 S = 3/2 function, P closed
32 O = 3/2 function, P A connected
33 R = 3/3 function, P, A and T closed
43 F = 4/3 function, P A B connected
43 G = 4/3 function, A B T connected
N = without push-in check valve or orifice (standard)
R = with push-in check valve, type RCA-5 (in P port)
D10 = with orifice disc, type D10 (in P port)
6 = ISO size 03 interface
B ... Q = standard model - see relevant data sheets
Z ... R = special features - please consult BUCHER
BG = with manual override
DI = without manual override
1 ... 9 = design number, seat valve (omit when ordering new units)
... = voltage e.g. 24 (24 V)
D = current DC
A = current AC
Ex. 246W2 32S
Nitrile seals
Viton seals
N N B B _ _EEx
7 Related data sheets
Reference (Old no.) Description
400-P-030501 (i-31) Size 03 interface to ISO 4401-03-02
400-P-110210 2/2 solenoid cartridge valve, type EEX-W1C… size 6
400-P-115115 3/2 solenoid cartridge valve, type EEX-W1D… size 6
D14-2117D Operating instructions for solenoid coil DC LISK
K14-2068D Operating instructions for solenoid coil AC LISK
D14-2130D3 Operating instructions for solenoid coil DC LISK IEC (on request)
D14-2078D3 Operating instructions for solenoid coil AC LISK IEC (on request)
E 2018 by Bucher Hydraulics AG Frutigen, CH-3714 Frutigen
www.bucherhydraulics.cominfo.ch@bucherhydraulics.com
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Classification: 430.300.-.315.315.300(W-2.23)