400-P-590101-EN-02/09.2023
Series DDRRZ-7011… to 7055…
2/6
Description, value, unitGeneral characteristics
Ambient temperature range -25°C … +50°C
MTTF
D
values 150 years, see data sheet 400-P-010101-en
Hydraulic characteristics Description, value, unit
Maximum operating pressure p
max
- standard model
(Inlet pressure)
- model “H”
70bar, pressure range “055”
50bar, pressure range “040”
40bar, pressure range “030”
30bar, pressure range “020”
20bar, pressure range “011”
100 bar, all pressure ranges
Flow range …15l/min
Nominal pressure ranges p
N
- model “055”
- model “040”
- model “030”
- model “020”
- model “011”
…55bar
…40bar
…30bar
…20bar
…11bar
Back pressure in T - static, not controlling
- while controlling
p
max
50bar
< 2 % p
N
Flow direction see symbols
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please contact BUCHER
Hydraulic fluid temperature range -25°C … +70°C
Viscosity range 15…380mm
2
/s (cSt), recommended 20...130mm
2
/s (cSt)
Minimum fluid cleanliness
Cleanliness class to ISO 4406:1999
class 18/16/13
Electrical characteristics Description, value, unit
Supply voltage 12V DC, 24V DC
Control current 12 V = 0…1400 mA, 24 V = 0…800 mA
Coil resistance R - cold value at 20°C
- cold value at -25°C
- max. warm value
12 V = 6.4Ω /24V = 17.2Ω
12 V = 5.2Ω /24V = 14.1Ω
12 V = 10.0Ω /24V = 27.0Ω
Inductance
Measured non-operated, at 0.1 mA (rms) / 1 kHz
12 V = 13 mH 24V = 38 mH
Recommended PWM frequency (dither) 200 Hz
Hysteresis with PWM 2…4 % I
N
Reversal error with PWM 2…4 % I
N
Sensitivity with PWM < 1 % I
N
Reproducibility with PWM < 2 % p
N
Relative duty cycle 100%
Nominal power consumption max. 19W
Insulation class to VDE 0580 H (180 °C)
Protection class to ISO20653 / EN60529 IP 65 / IP 67, see “Ordering code”
(with appropriate mating connector and
proper fitting and sealing)
Electrical connection DIN EN 175301-803, 3-pin 2 P+E (standard)
for other connectors, see “Ordering code”