Pressure-Relief Cartridge Valve, Size 10
Q
max
= 140l/min,p
max
= 450bar
Direct acting, positive seat design
Series DDPB-1C…
1/4
Reference: 400-P-270101-EN-01
Issue: 09.2021
S Positive seat design gives near zero-leakage closure
of ports A and B
S Good override characteristics due to dynamic poppet
stroke assistance
S Pressures to 450 bar, all ports (see spring ranges in
model code key)
S Ideal for back-pressure and anti-shock service (fast and
stable response)
S Available as cartridge or in DC-12-line mounting body
S Also available in ISO / CETOP 05 stack-mounting bodies
(315 bar max.)
1. Description
Series DDPB-1C-10 ... cartridges are direct acting pres
sure relief valves. Their positive seat design ensures vir
tually zero-leakage, and they are designed to fit BUCHER
cavity type DC. The spring chamber is internally drained to
port B. Any pressure in port B is additive to the spring pres
sure setting, therefore port B should preferably be con
nected to tank (see also externally drained model
DDPB-3D ...). Thoroughly oil or grease external seals be
fore fitting the cartridge in a DC cavity. The cartridge can be
tightened with a 27 A/F OE spanner (note the recom
mended tightening torque). Form tools are available for
sale or hire, should customers wish to machine their own
cavities. For line- and manifold mounting body type DC-12
see related data sheet.
2. Symbols
BA
DDPB-1C-10 ...
3. Characteristics
Type pressure relief cartridge valve
Design direct acting, positive seat (poppet)
Mounting method screw-in cartridge
Size 10 mm nominal size, BUCHER cavity DC
Mass kg 0,35
Mounting attitude unrestricted
Flow direction A = pressure inlet, B = pressure outlet (Tank)
Operating pressure bar ... 450 max. in A and B
Adjustment ranges,
see performance curves
bar pressure range P = 350 ... 450
pressure range O = 300 ... 400
pressure range N = 180 ... 350
pressure range M = 80 ... 240
pressure range L = 10 ... 100
Flow rate Q max. l/min 140, see performance limits
Fluids Hydraulic oils HL and HLP to DIN 51 524
other fluids - contact BUCHER
Fluid temperature range _C -25 ... +80
Viscosity range cSt 10 ... 650 mm
2
/s, recommended 15 … 250 mm
2
/s
Minimum fluid cleanliness 20/18/15 to ISO 4406 : 1999