2/5
Type series: DCPS-10-_-A-…
Reference: 520-P-090120-EN-01/01.2021
Technical data
General Characteristics Description, value, unit
Function group Directional valve
Function 3-way/2-position
Design Screw-in cartridge valve
Controls hydraulical operation
Characteristic direct acting, spool type
Transition/central position of spool/piston zero overlap or underlap (open)
Construction size SAE 10 / nominal size 8
Thread size 7/8-14 UNF-2A
Mounting attitude unrestricted
Weight 0.21 kg
Cavity acc. factory standard For cavity C1040
Tightening torque steel 77.5 Nm
Tightening torque aluminium 50.5 Nm
Tightening torque tolerance ± 5 %
Minimum ambient temperature - 40 °C
Maximum ambient temperature + 120 °C
Surface protection All external parts zinc plated, chromited (CrVI-free)
Available seal types several seal types available, see ordering code
Seal kit order number NBR: SKN-1042 / FKM: SKV-1042
Hydraulic Characteristics Description, value, unit
Maximum operating pressure 350 bar
Maximum ow rate 46 l/min
Flow direction see symbol
Hydraulic uid
All general purpose hydraulic uids such as MIL-H-5606, SAE-
#10, SAE-#20, etc.
Minimum uid temperature - 25 °C
Maximum uid temperature + 80 °C
Viscosity range 10 … 500 mm²/s (cSt)
Recommended viscosity range 20 … 130 mm²/s (cSt)
Minimum uid cleanliness (cleanlineless class according to ISO
4406:1999)
class 18/16/13
Minimum set pressure 5.3 bar
Maximum set pressure 14 bar
Internal leakage ow rate 82 cc/min at 350 bar
Pilot operating media hydraulic uid