6 Installation information
IMPORTANT!
To achieve the maximum performance rating, fit
the solenoid coil as shown (with the plug pins at
the bottom) and install the valve in a steel body.
When fitting the cartridges, note the mounting atti
tude (preferably vertical, with coil down → auto
matic air bleed) and use the specified tightening
torque. No adjustments are necessary, since the
cartridges are set in the factory.
ATTENTION!
To prevent any pressure surges, port 1 must be
routed to tank with the least possible back-pres
sure. Any tank pressure acting at port 1 is additive
to the pressure setting at the main port 2.
ATTENTION!
Only qualified personnel with mechanical skills
may carry out any maintenance work. Generally,
the only work that should ever be undertaken is to
check, and possibly replace, the seals. When
changing seals, oil or grease the new seals tho
roughly before fitting them.
7 Manual pressure setting
The proportional pressure relief cartridges are equipped
with manual emergency pressure adjustment as standard.
This allows the desired pressure value to be set mechani
cally, e.g. in the event of failure of the electrical control or the
proportional solenoid. The emergency pressure setting is
not intended for adjusting pressure values in solenoid oper
ation and must then be reset to the factrory setting.
IMPORTANT!
Any changes to the manual emergency pressure
setting have a direct effect on the factory settings.
4
C
E
D
13
M
A
= 10 [Nm] ± 10 %
H Protective cap
I Lock nut (13 A/F)
J Adjusting spindle for pressure setting
Setting the pressure manually
Steps:
Remove the protective cap.
Slacken the lock nut (13 A/F).
Screw in (turn to right) the adjusting spindle (4 A/F) until the
required pressure is set.
Tighten the lock nut (13 A/F).
Fit the protective cap.
ATTENTION!
To reset the inverse proportional pressure-relief
cartridges to their initial position (the factory set
ting), a constant flow rate and a pressure gauge
that measures the pressure in the main port 2 are
needed.
Restoring the factory settings
Steps:
Solenoid de-energised.
Remove the protective cap.
Slacken the lock nut (13 A/F).
Unscrew the adjusting spindle (4 A/F) to its end-stop, then
screw it in until the pressure on the gauge just starts to
rise.
Unscrew the spindle again by:
250 bar = 1/4 of a turn
160, 110, 70 bar = 1/2 of a turn
45, 18 bar = 3/4 of a turn
Tighten the lock nut (13 A/F).
Fit the protective cap.