Coils for Solenoid Valves
Diverse connector types, power ratings and voltages
Series D45/22...
1/4
Reference: 400-P-120130-EN-01
Issue: 09.2022
S Facilitates compact assemblies
S All common DC voltages
S Nominal power up 22W
S Diverse connector types
S Protection class IP65 / IP67 / IP69K
S For core tube j22 mm
1 Description
The slip-on coils can be replaced without opening the hy
draulic envelope and can be positioned at any angle
through 360°. When combined with the appropriate core
tube, the coils produce an on/off solenoid function or a pro
portional solenoid function. Thanks to the wide variety of
connector types and voltages, these coils are suitable for
widespread use in mobile and industrial applications. These
coils are very adaptable in use, a benefit that is enhanced
by various power ratings. The plug base are plastic. The
body is zinc-nickel plated according to DIN 50979 and is
thus suitable for use in the harshest operating environ
ments.
2 Symbol
Connector type to DIN EN 175301-803
Direct current DC
IN
UN
R20
IMPORTANT!
For solenoid coils with integrated rectifier as well
as for solenoid coils without protection diode the
two supply connections (U
N
) can be inter
changed. The earth connection is marked with …
All connector types except DIN EN 175301-803 (DC)
Without protection diode
R20
IN
UN
3 Technical data
General characteristics Description, value, unit
Designation coil, D45/22
Design slip-on, rotatable 360°
Mounting method core tube, knurled nut
400-P-120130-EN-01/09.2022
Solenoid coil, series D45/22…
2/4
Description, value, unitGeneral characteristics
Ambient temperature range 14 W
22 W
8 W
-30°C … +65°C (Prop.)
-30°C … +65°C (ON/OFF)
-30°C … +80°C (ON/OFF)
Coil weight 530 g
Electrical characteristics Description, value, unit
Electrical connection: standard
on request
on request
on request
- DIN EN 175301-803, 3-pole 2 P+E
- Deutsch plug connection DT04-2P
- Junior Timer radial plug connection, 2-pole
- AMPSEAL axial plug connection
Insulation class to VDE 0580 H (180°C)
Protection class to ISO20653 / EN60529 IP 65 / IP 67 / IP 69K, see “Ordering code”
(with appropriate mating connector and
proper fitting and sealing)
Relative duty cycle 100%
Control current see valve data sheet (proportional function)
Supply voltage tolerance ±10%
Supply voltages / power ratings:
standard
standard
Others on request
12V DC / 14 W, 22 W
24V DC / 14 W, 22 W
IMPORTANT!:
1)
supply voltages > 75 VDC or 50 VAC only
possible with DIN EN 175301-803 connect.
Supply voltage: 12VDC 14W 22W
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
2.6Ω
2.1Ω
4.1Ω
6.28Ω
5.1Ω
9.8Ω
Inductance parallel 120 Hz
Measured at the core tube, non-operated serial 1000 Hz
42mH
8 mh
--mH
--mH
Supply voltage: 24VDC 14W 22W
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
10.1Ω
8.1Ω
15.8Ω
26.4Ω
21.2Ω
41.3Ω
Inductance parallel 120 Hz
Measured at the core tube, non-operated serial 1000 Hz
170mH
33 mH
445mH
90 mH
400-P-120130-EN-01/09.2022
Solenoid coil, series D45/22…
3/4
4 Dimensions
Coil with DIN EN plug connection
S Standard-Type G (see Ordering code)
* Free space for
plug assembly
29.6
22.1
34.2
19.4
45.3
50.1
33.7
68.4
88
12
*
Coil with Junior Timer axial plug connection
S Type I (see ordering code)
22.1
45.3
20
29.3
50.1
65.3
35.3
Coil with Deutsch DT04-2P plug connection
S Type T (see Ordering code)
22.1
50.1
45.3
31.2
63.4
19.8
37.4
Coil with AMPSEAL 16 axial plug connection
S Type A (see ordering code)
22.1
50.1
45.3
63.7
31.3
19.8
35
5 Installation information
Attention.
Because of the danger of overheating, the coil
must only be operated when it is properly fitted on
a valve.
Attention.
Delivery is done without mating connector.
400-P-120130-EN-01/09.2022
Solenoid coil, series D45/22…
4/4
6 Ordering code
COIL = coil
D45/22 = Ğ Ğ) / Ğ Ğ)
B = use for a switching valves (8 W, 22 W)
P = use for a prop. Valves (14 W)
... = voltage e.g. 24 (24 V),
D = current DC
G = standard
for the following plug−variants, please consult Bucher:
= Nominal power consumption, see “Electrical characteristics
Ex. 24 22WD _D45/22COIL _
mating plug
not supplied
7 Related data sheets
Reference Description
400-D-9010002 Technical hints and tips – solenoid coils
E 2024 by Bucher Hydraulics AG Frutigen, CH-3714 Frutigen
www.bucherhydraulics.cominfo.ch@bucherhydraulics.com
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Classification: 430.395.…