Coils for Solenoid Valves
Wide variety of connector types, power ratings and voltages
Series D36...
1/6
Reference: 400-P-120110-EN-08
Issue: 02.2024
S Facilitates compact assemblies
S All common AC and DC voltages
S Power consumption 8W, 17W, 27/25W
S Wide variety of connector types
S With optional protection diode
S Protection class IP65 / IP67 / IP69K
S For core tube j16 mm
1 Description
The slip-on coils can be replaced without opening the hy
draulic envelope and can be positioned at any angle
through 360°. When combined with the appropriate core
tube, the coils produce an on/off solenoid function or a pro
portional solenoid function. Thanks to the wide variety of
connector types and voltages, these coils are suitable for
widespread use in mobile and industrial applications. These
coils are very adaptable in use, a benefit that is enhanced
by various power ratings and an optional protection diode.
The coil encapsulation and the plug base are glass-fibre re
inforced thermoplastic.
2 Symbol
Connector type to DIN EN
Direct current DC Alternating current AC
All connector types except DIN EN (DC)
Without protection diode With bipolar protection diode
IN
UN
R20
R20
IN
UN
ATTENTION!
Protection of AC solenoid coils.
The rectifier built into the coil can be damaged by
high voltage spikes.
To prevent AC coils from being destroyed, a mat
ing connector with integral power varistor is re
commended.
IMPORTANT!
For solenoid coils with integrated rectifier as well
as for solenoid coils without protection diode and
for solenoid coils with bipolar protection diode the
two supply connections (U
N
) can be inter
changed. The earth connection is marked with …
ATTENTION!
Coils with a bipolar protection diode:
To protect the diode in the coil against overvoltage
and overcurrent the related data for this diodes
must be observed!
400-P-120110-EN-08/02.2024
Solenoid coil, series D36…
2/6
3 Technical data
General characteristics Description, value, unit
Designation coil, D36
Design slip-on, rotatable 360°
Mounting method core tube, knurled nut
Ambient temperature range -30°C … +50°C
Coil weight 190 … 230 g (dependent on type of connection)
Electrical characteristics Description, value, unit
Electrical connection - DIN EN 175301-803, 3-pole 2 P+E
- Deutsch plug connection 45° DT04-2P
- Junior Timer radial plug connection, 2-pole
- Junior Timer axial plug connection, 2-pole
- AMP Super Seal 1,5 / Metri-Pack 150, 2-pole
- Kostal plug connection M27x1, 2-pole
- flying leads, 2-pole
Insulation class to VDE 0580 H (180°C)
Protection class to ISO20653 / EN60529 IP 65 / IP 67 / IP 69K, see “Ordering code”
(with appropriate mating connector and
proper fitting and sealing)
Relative duty cycle 100%
Control current see valve data sheet (proportional function)
Supply voltage tolerance ±10%
Supply voltages / power ratings:
standard
standard
standard
standard
More on request
12V DC / 8 W, 17 W, 27 W
24V DC / 8 W, 17 W, 27 W
26V DC / 27 W
28V DC / 17 W, 27 W
200V DC / 25 W
115VAC (50…60 Hz)
1)
/ 17 VA, 25 VA
230VAC (50…60 Hz)
1)
/ 17 VA, 25 VA
see Coil resistance R
Bipolar protection diode 12 V DC: P6KE33CA
24, 26, 28 V DC: P6KE56CA
Nominal breakdown voltage of the bipolar protection diode 12 V DC: 33 V
24, 26, 28 V DC: 56 V
Max. allowed voltage peaks for 1 second and relative duty
cycle ED = 0.4 %
12 V DC: 25 V
24, 26, 28 V DC: 43 V
IMPORTANT!:
1)
supply voltages > 75 VDC or 50 VAC only
possible with DIN EN 175301-803 connect.
Supply voltage: 12VDC 8W 17W 27W
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
18.0Ω
14.5Ω
28.2Ω
8.6Ω
6.9Ω
13.5Ω
5.8Ω
4.7Ω
9.1Ω
Inductance parallel 120 Hz
Measured at the core tube, non-operated, at 0.1 mA (rms) / 1 kHz serial 1000 Hz
204mH
51 mH
107mH
28 mH
62mH
16 mH
400-P-120110-EN-08/02.2024
Solenoid coil, series D36…
3/6
Supply voltage: 24VDC 8W 17W 27W
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
72.0Ω
58.0Ω
112.7Ω
34.9Ω
28.1Ω
54.6Ω
20.9Ω
16.8Ω
32.7Ω
Inductance parallel 120 Hz
Measured at the core tube, non-operated, at 0.1 mA (rms) / 1 kHz serial 1000 Hz
765mH
193 mH
416mH
108 mH
246mH
62 mH
Supply voltage: 26VDC 8W 17W 27W
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
25.0Ω
20.1Ω
39.1Ω
Inductance parallel 120 Hz
Measured at the core tube, non-operated, at 0.1 mA (rms) / 1 kHz serial 1000 Hz
292mH
74 mH
Supply voltage: 28VDC 8W 17W 27W
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
45.0Ω
36.2Ω
70.4Ω
28.0Ω
22.5Ω
43.8Ω
Inductance parallel 120 Hz
Measured at the core tube, non-operated, at 0.1 mA (rms) / 1 kHz serial 1000 Hz
558mH
143 mH
350mH
91 mH
Supply voltage: 200VDC 8W 17W 25W
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
1710Ω
1377Ω
2677Ω
Inductance parallel 120 Hz
Measured at the core tube, non-operated, at 0.1 mA (rms) / 1 kHz serial 1000 Hz
16'350mH
4'390 mH
Supply voltage: 115VAC 8VA 17VA 25VA
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
630Ω
507Ω
986Ω
430Ω
346Ω
673Ω
Supply voltage: 230VAC 8VA 17VA 25VA
Coil resistance R - cold value at +20°C
- cold value at -30°C
- max. warm value
2520Ω
2029Ω
3945Ω
1710Ω
1377Ω
2677Ω
400-P-120110-EN-08/02.2024
Solenoid coil, series D36…
4/6
4 Dimensions
Coil with DIN plug connection
S Standard-Type (see Ordering code)
Ø36
18 9
53
1.5
Ø18.85
Ø16.2
22.9
52.9
72.5
12*
*Freiraum für Steckermontage / free space for plug assembly
Coil with Deutsch DT04-2P plug connection
S Type D without quenching diode
Type DT with quenching diode (see Ordering code)
Ø36
53
22.9
25.9
61.7
1.5
Ø16.2
Ø18.85
Coil with Junior Timer radial plug connection
S Type JT with quenching diode (see ordering code)
Ø36
18
53
27.8
58.8
Ø16.2
1.5
Ø18.85
Coil with Junior Timer axial plug connection
S Type IT (see ordering code)
53
3.5 24.2
55.8
Ø36
Ø16.2
1.5
30.3
Ø18.85
Coil with Kostal plug connection
S Type C (see ordering code)
8
Ø36
18
53
60.9
22.9 10 10
M27x1
Ø16.2
1.5
Ø18.85
Coil with flying leads/
flexible wires 1mm
2
; insulation FEP (Teflon)
S Type F (see ordering code)
Ø36
10
18
53
50.9
1022.9 ca. 500
1.5
Ø16.2
Ø18.85
6
400-P-120110-EN-08/02.2024
Solenoid coil, series D36…
5/6
Coil with connection AMP Superseal/
Metri Pack 150, 2-pole
S Type S (see ordering code)
Ø16.2
1.5
Ø36
53
17.8 0.4
23.1
62.1
Ø18.85
5 Installation information
Attention.
Because of the danger of overheating, the coil
must only be operated when it is properly fitted on
a valve. To prevent the ingress of water, both ends
of the coil on the core tube must be properly
sealed with O-rings.
Attention.
To obtain the maximum performance, the position
of the plug socket must be ensured when mount
ing the solenoid coil. The correct position can be
found in the corresponding data sheet.
5.1 Minimum distance for solenoid coils
To ensure the specified performance data of the proportio
nal valve is achieved, a minimum distance between the so
lenoid coils must be maintained when designing a sub-sys
tem (manifold block).
This information pertains to proportional valves that are
equipped with these solenoid coils and are installed in the
immediate proximity of a solenoid valve which is si
multaneously energized.
Solenoid coil types:
Recommended distances (mm)
36x48 zu 36x48
a b
36x48 zu D36
a b c
D36 zu D36
c
Aluminum block 7 4 2 4 8 8
Steel block 12 12 12 6 10 10
400-P-120110-EN-08/02.2024
Solenoid coil, series D36…
6/6
6 Ordering code
D36 = Ğ Ğ)
... = voltage e.g. 24 (24 V)
D = current DC
(blank) = standard plug connection to DIN EN (3−pole, 2 P+E)
JT = Junior Timer radial plug connection (with protection diode, IP65)
IT = Junior Timer axial plug connection (with protection diode, IP65)
F = flying leads (500 mm)
= Nominal power consumption, see “Electrical characteristics“
Ex. 24 27WD _D36MAG−SP
mating plug
not supplied
7 Related data sheets
Reference Description
400-D-9010002 Technical hints and tips – solenoid coils
E 2024 by Bucher Hydraulics AG Frutigen, CH-3714 Frutigen
www.bucherhydraulics.cominfo.ch@bucherhydraulics.com
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Classification: 430.395.…