4/10 MHDRE 06 SK | Proportional pressure reducing valve
Bosch Rexroth AG, RE 64655, edition: 2015-01
Technical data
(For applications outside these parameters, please consult us!)
General
Mass kg 0.7
Installation position any — if it is ensured that no air can collect upstream of the valve.
Otherwise, we recommend suspended installation of the valve.
Ambient temperature range °C See “Admissible working range” on page 5
Storage temperature range °C −40 … +80
Salt spray test according to EN ISO 9227 h 720 (NSS test)
Solenoid surface protection Coating according to DIN 50962-Fe//ZnNi with thick film passivation
Hydraulic
Maximum control pressure ▶ Main port ① bar 18; 20; 26; 30
Maximum inlet pressure ▶ Main port ② bar 100
Maximum counter pressure ▶ Main port ③ bar Depressurized (max. 100 bar; the tank pressures that occur are
added to the control pressure (main port ①))
Max. flow l/min See characteristic curves page 6
Maximum leakage ▶ Main port ③ ml/min 120 (50 bar in ②; I = 0 mA, 46 cSt)
Maximum pilot oil ml/min 120 (50 bar in ②; I = I
max
, 46 cSt)
Hydraulic fluid see table below
Hydraulic fluid temperature range °C −40 … +120
Viscosity range mm
2
/s 5 … 400
Maximum admissible degree of contamination of the
hydraulic fluid
Cleanless class according to ISO 4406 (c)
Class 20/18/15
1)
Hysteresis (within the tolerance band) bar ≤ 1.5 (control pressure 18, 20 bar)
≤ 2.0 (control pressure 26, 30 bar)
Step response (T
u
+ T
g
) 0 % → 100 %; 100 % → 0 % ms ≤ 60 (50 bar in ②; 46cSt, q
V
= 0 l/min, dead volume in ① 140 cm
3
)
Repetition accuracy % < 2 % of the maximum control pressure
Load cycles 10 million
Strainer element on the main port ② (P) µm 240
1)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents faults
and at the same time increases the life cycle of the components.
For the selection of the filters see www.boschrexroth.com/filter.
We recommend using a filter with a minimum retention rate of
ß
10
≧ 75.
Hydraulic fluid Classification Suitable
sealing materials
Standards Data sheet
Mineral base oils HL, HLP NBR, FKM DIN 51524 90220
Bio-degradable ▶ insoluble in water HEES FKM ISO15380 90221
▶ soluble in water HEPG FKM ISO15380
Important information on hydraulic fluids:
▶ For more information and data about the use of other hydraulic
fluids, refer to data sheets above or contact us!
▶ There may be limitations regarding the technical valve data (tem-
perature, pressure range, life cycle, maintenance intervals, etc.).
▶ The flash point of the hydraulic fluid used must be 40 K higher
than the maximum solenoid surface temperature.
▶ Bio-degradable: When using bio-degradable hydraulic fluids that
are also zinc-solving, zinc may accumulate in the fluid (700mg zinc
per pole tube).