Proportional pressure reducing valve | FTDRE4K 5/10
RE 58038, edition: 2014-04, Bosch Rexroth AG
3)
Due to the surface temperatures of the solenoid coils, the
standards ISO 13732-1 and ISO4413 need to be adhered to!
4)
The chopper frequency is to be optimized depending on
theapplication.
In this regard, observe the working temperature range of
theapplication.
electric
Voltage type Direct voltage
Supply voltages V 12 DC 24 DC
Maximum solenoid current mA 1800 800
Coil resistance (cold value at 20 °C) Ω 2.4 12
Duty cycle % 100
See characteristic curves page 7.
Maximum coil temperature
3)
°C 150
Protection class according to VDE 0470-1
(DIN EN 60529)
DIN 40050-9
▶ Version "C4" IP 65 with mating connector mounted and locked
IP 67 and IP 69K with Rexroth mating connector (material no.
R901022127)
▶ Version "K40" IP 67 and IP 69K with mating connector mounted and locked
Control electronics (separate order) Analog amplifier type RA... (data sheet 95230)
BODAS control unit type RC... (data sheet 95200)
Recommended dither frequency (PMW)
Chopper frequency (recommended)
4)
Hz 200
Design according to VDE0580
When establishing the electrical connection, the protective
earthing conductor (PE
) has to be connected correctly.
Technical data
(For applications outside these parameters, please consult us!)
Hydraulic fluid Classification Suitable sealing materials Standards
Mineral oils HL, HLP FKM DIN 51524
Bio-degradable – insoluble in water HEES FKM VDMA 24568
– soluble in water HEPG FKM
Important information on hydraulic fluids!
▶ For more information and data on the use of other hydraulic
fluids, please refer to data sheet 90220 or contact us.
▶ There may be limitations regarding the technical valve data (tem-
perature, pressure range, life cycle, maintenance intervals, etc.)!
▶ The flash point of the hydraulic fluid used must be 40 K higher
than the maximum solenoid surface temperature.
▶ Bio-degradable: If bio-degradable hydraulic fluids are used that
are also zinc-solving, there may be an accumulation of zinc.