Hydraulics Bosch Rexroth AGRE 29077/03.10 4WRVE 10...27
5/16
Technical data
general
Type Spool valve, pilot operated
Actuation Directional control valve size 6 - OBE, with position controller for
pilot control valve and main stage
Type of connection Subplate mounting, porting pattern according to ISO 4401-...
Installation position Any
Ambient temperature range °C –20...+50
Weight kg Size 10 8.0 Size 16 10.4 Size 25 18.2 Size 27 18.2
Vibration resistance, test condition Max. 25 g, room vibration test in all directions (24 h)
hydraulic (measured with HLP 46, ϑ
oil
= 40 °C ±5 °C)
Hydraulic fluid Hydraulic oil according to DIN 51524…535, other media upon request
Viscosity range recommended mm
2
/s 20...100
max admissible mm
2
/s 10...800
Hydraulic fluid temperature range °C –20...+65
Maximum admissible degree of contamination of the
hydraulic fluid
cleanliness class according to ISO 4406 (c) Class 18/16/13
1)
Flow direction According to symbol
Rated flow at
Δp = 5 bar per edge
2)
Size 10 Size 16 Size 25 Size 27
l/min 40 55 70 85 90 120 150 200 300 370 430
Max. operating
pressure
Ports P, A, B
external pilot oil supply bar 350 350 350 350
Ports P, A, B
internal pilot oil supply bar 250
Ports T, X, Y bar 250
Min. pilot oil pressure "pilot control stage" bar 10
Q
max
l/min 170 450 900 1000
Q
N
pilot control valve l/min 8 24 40 40
Zero flow pilot control valve at 100 bar cm
3
/min < 180 < 300 < 500 < 500
Zero flow main stage at 100 bar cm
3
/min < 400 < 600 < 1000 < 1000 < 1000
static / dynamic
Hysteresis % < 0.1 hardly measurable
Manufacturing toleranceQ
max
% < 10
Actuating time for signal step
(at X = 100 bar)
0...100 % 12 15 23 23
0...10 %0 6 7 10 10
Actuating time for signal step
(at X = 10 bar)
0...100
% 40 50 90 90
0...10 %0 20 20 30 30
Switch-off behavior after electrical shut-off: Pilot control valve not defined in P-B/A-T or P-
A/B-T, main stage can be completely controlled (PB/AT or PA/BT)
Temperature drift Zero shift < 1% at ∆T = 40 °C
Zero compensation ex factory ±1 %
1)
The cleanliness classes specified for the components must be complied with in hydraulic systems.
Effective filtration prevents faults and at the same time increases the service life of the components.
For the selection of the filters, see technical data sheets RE 50070, RE 50076 and RE 50081.
2)
Flow with different ∆p
Q
x
= Q
nom
•
Δp
x
5