general
Sizes Size 6 10
Weight – Type 4WRE kg 2.2 6.3
– Type 4WREE kg 2.4 6.5
Installation position Any, preferably horizontal
Ambient temperature range – Type 4WRE °C –20 to +70
– Type 4WREE °C –20 to +50
Storage temperature range °C –20 to +80
MTTF
d
values according to EN ISO 13849 Years 150
1)
(for more information see data sheet 08012)
hydraulic (measured with HLP46, ϑ
Oil
= 40 °C ± 5 °C and p = 100 bar)
Maximum operating
pressure
– Port A, B, P bar 315
– Port T bar 210
Rated flow q
V rated
with Δp = 10 bar l/min 4, 8, 16, 32 25, 50, 75
Recommended maximum flow l/min 80 180
Hydraulic fluid See table below
Hydraulic fluid temperature range °C –20 to +80 (preferably +40 to +50)
Viscosity range mm
2
/s 20 to 380 (preferably 30 to 46)
Maximum admissible degree of contamination of the hydraulic fluid,
cleanliness class according to ISO 4406 (c)
Class 20/18/15
2)
Hysteresis % ≤0.1
Range of inversion % ≤0.05
Response sensitivity % ≤0.05
Zero shift upon change of hydraulic
fluid temperature and operating pressure
%/10 K ≤0.15
%/100 bar ≤0.1
1)
With control spool types E, E1, EA, W, W1, WA; in longitudinal control spool direction, there is sufficient positive overlap
without shock/vibration load; observe the installation orientation with regard to the main direction of acceleration.
2)
The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents
faults and at the same time increases the service life of the components.
For the selection of the filters see www.boschrexroth.com/filter
Hydraulic fluid Classification Suitable sealing
materials
Standards
Mineral oils and related hydrocarbons HL, HLP NBR, FKM DIN 51524
Flame-resistant – Containing water
HFC (Fuchs HYDROTHERM 46M,
Petrofer Ultra Safe 620)
NBR ISO 12922
Important information on hydraulic fluids!
– For more information and data on the use of other hydrau-
lic fluids refer to data sheet 90220 or contact us!
– There may be limitations regarding the technical valve
data (temperature, pressure range, service life, mainte-
nance intervals, etc.)!
– The flash point of the process and operating medium used
must be 40 K higher than the maximum solenoid sur-
face temperature.
– Flame-resistant – water-containing: Maximum pressure
differential per control edge 175 bar. Pressure pre-loading
at the tank port > 20 % of the pressure differential; other-
wise, increased cavitation.
Life cycle as compared to operation with mineral oil HL,
HLP 50 % to 100 %.