6/16 Bosch Rexroth AG Hydraulics
4WRA; 4 WRAE
RE 29055/10.05
Technical data (for applications outside these parameters, please consult us!)
Electical
Nominal size NS
610
Voltage type DC
Command value signal Voltage input „A1“ V ±10
with type WRAE Current input „F1“ mA 4 to 20
Max. current per
solenoid
A 2.5
Solenoid coil Cold value at 20 °C
Ω
2
resistance Max. warm value
Ω
3
Duty % 100
Max. coil temperature
1)
°C 150
Electrical connections 4WRA with component plug to DIN EN 175301-803 or ISO 4400
see page 7 plug-in connector to DIN EN 175301-803 or ISO 4400
2)
4WRAE with component plug to DIN EN 175201-804
plug-in connector DIN EN 175201-804
2)
Valve protection to EN 60529 IP65 with mounted and fixed plug-in connector
Control electronics
For 4WRA
Digital amplifier in Eurocard format
2)
VT-VSPD-1-2X
( to RE 30523 - middle of 2006)
Analogue amplifier in Eurocard format
2)
VT-VSPA2-1-2X/… to RE 30110
Analogue module amplifier
2)
VT-MSPA2-1-1X
to RE
30228
For 4WRAE integrated into the valves, see page 8
Analogue command value module VT- SWMA-1-1X/... to RE 29902
Analogue command value module VT-SWMKA-1-1X/... to RE 29903
Digital command value card VT-HACD-1-1X/… to RE 30143
Analogue command value card
VT-SWKA-1-1X/... to RE 30255
Supply voltage Nominal voltage VDC 24
4WRAE, 4WRA
3)
Lower limiting value V 21 / 22 (4WRA);
19 (4WRAE)
Upper limiting value V 35
Amplifier current
I
max
A1.8
consumption Max. impulse current A 3
1)
Due to the occurring surface temperature of the solenoid
coils, the European Standards DIN EN 563 and DIN EN 982
must be taken into account!
2)
Separate order
3)
With Bosch Rexroth AG control electronics
Note: For details regarding the environmental
simulation test covering EMC (electro-
magnetic compatibility), climate and
mechanical loading see RE 29055-U
(declaration regarding environmental
compatibility).