Hydraulics Bosch Rexroth AGRE 29047/09.05 4WRBA..EA..
5/16
Technical data
General
Construction Spool-type valve
Actuation Proportional solenoid without position control,
external amplifier
Connection type Subplate, mounting hole configuration NG6 (ISO 4401-03-02-0-94),
NG10 (ISO 4401-05-04-0-94)
Mounting position Optional
Ambient temperature range °C –20...+50
Weight NG61 kg 2.0 (2.2 with manual adjustment)
NG10 kg 6.9
Vibration resistance, test condition
Max. 25 g, shaken in 3 dimensions (24 h)
Hydraulic (measured with HLP 46,
oil
= 40 °C ±5 °C)
Pressure fluid Hydraulic oil to DIN 51524...535, other fluids after prior consultation
Viscosity range recommended mm
2
/s 20...100
max. permitted mm
2
/s 10...800
Pressure fluid temperature range °C –20...+80
Maximum permitted degree of
contamination of pressure fluid
Purity class to ISO 4406 (c)
Class 18/16/13
1)
Direction of flow, see symbol
NG6 NG10
Nominal flow rate (at ∆p = 5 bar)* l/min
14 28 (per channel) 32 63 (per channel)
Leakage per metering I
m
= 0
edge (∆p = 100 bar) cm
3
/min
80 80
I
m
= max.
cm
3
/min
150
Max. working pressure bar Port P, A, B: 315
Port T: 250
1)
The purity classes stated for the components must be
complied with in hydraulic systems. Effective filtration
prevents problems and also extends the service life of
components.
For a selection of filters, see catalog sheets RE 50070,
RE 50076 and RE 50081.
* Nominal flow
This is always based on a pressure differential of ∆p = 5 bar
at the throttling point.
Where other pressure differentials are involved, the flow is
calculated according to the following formula:
∆p
X
Q
x
= Q
nom
·
冪莦
5
However, the operating limits must be borne in mind.
If they are exceeded, the ensuing flow forces lead to
uncontrollable spool movements. Pressure compensators
are used to reliably limit ∆p.